Difference between revisions of "SLS 88.150 (Secondary Air Control)"
From Nefmoto
(4 intermediate revisions by one user not shown) | |||
Line 3: | Line 3: | ||
See the ''funktionsrahmen'' for the following diagrams: | See the ''funktionsrahmen'' for the following diagrams: | ||
− | sls-sls Function overview | + | sls-sls: Function overview |
− | slson Conditions for switching on secondary air | + | slson: Conditions for switching on secondary air |
− | slsoff Conditions for switching off secondary air | + | slsoff: Conditions for switching off secondary air |
− | sls-slp Conditions for setting the bits of SLP | + | sls-slp: Conditions for setting the bits of SLP |
− | sls-bmsl Calculating the secondary air mass | + | sls-bmsl: Calculating the secondary air mass |
− | sls-dichte Calculating the correction | + | sls-dichte: Calculating the air density correction factor for the secondary air mass |
− | + | ||
− | sls-bslpdyn Description of the dynamic of the secondary air pump | + | sls-bslpdyn: Description of the dynamic of the secondary air pump |
− | sls-bslsoff Description of the secondary air dynamic in the exhaust system | + | sls-bslsoff: Description of the secondary air dynamic in the exhaust system |
− | sls-bfmlssl Calculation of enrichment due to secondary air | + | sls-bfmlssl: Calculation of enrichment due to secondary air |
− | sls-bkt Secondary air adaption/short journey | + | sls-bkt: Secondary air adaption/short journey |
sls-e-slpe E_SLPE: error flag secondary air pump | sls-e-slpe E_SLPE: error flag secondary air pump | ||
Line 27: | Line 27: | ||
sls-e-slve E_SLVE: error flag secondary air valve | sls-e-slve E_SLVE: error flag secondary air valve | ||
− | sls-e-slpanst Evaluation of the SLP-output stage | + | sls-e-slpanst: Evaluation of the SLP-output stage |
− | sls-slvanst Evaluation of the SLV-output stage | + | sls-slvanst: Evaluation of the SLV-output stage |
− | sls-z-sls Cycle flag: secondary air control (cylinder bank 1) | + | sls-z-sls: Cycle flag: secondary air control (cylinder bank 1) |
− | sls-z-sls2 Cycle flag: secondary air control (cylinder bank 2) | + | sls-z-sls2: Cycle flag: secondary air control (cylinder bank 2) |
− | sls-init Initialisation | + | sls-init: Initialisation |
− | sls-swoff ECU delay | + | sls-swoff: ECU delay |
Line 60: | Line 60: | ||
− | <u>Switch-off/termination Conditions | + | <u>Switch-off/termination Conditions</u> |
− | + | The secondary air is terminated | |
· When the threshold IMLSLMX is crossed (B_slpoff = 1) | · When the threshold IMLSLMX is crossed (B_slpoff = 1) | ||
Line 102: | Line 102: | ||
− | <u>Calculation of Enrichment due to Secondary Air | + | <u>Calculation of Enrichment due to Secondary Air</u> |
Bit 3 of the code word CWSLS determines whether there is lambda-engine set point during secondary air injection via map KFLMSKH from function LAKH (flmssl = 0) or whether there is lambda-exhaust set-point, including secondary air via map KFLASKH from function LAKH (flmssl = 1) from an automatic calculation of the required lambda-engine ​​with consideration of the secondary air dilution factor flamsl. Designs with lambda-exhaust set point can also be dependent on bit 4 realized after leaving the debounced idle or inputting the driving phase (bit 5) of the transition to lambda-engine through a filter with time constants ZFLMSSL. Via bit 2 of the codeword CWSLS, one can select whether with transition from B_slsoff or B_sls flmssl from the PT1-filter output is switched hard to 0. | Bit 3 of the code word CWSLS determines whether there is lambda-engine set point during secondary air injection via map KFLMSKH from function LAKH (flmssl = 0) or whether there is lambda-exhaust set-point, including secondary air via map KFLASKH from function LAKH (flmssl = 1) from an automatic calculation of the required lambda-engine ​​with consideration of the secondary air dilution factor flamsl. Designs with lambda-exhaust set point can also be dependent on bit 4 realized after leaving the debounced idle or inputting the driving phase (bit 5) of the transition to lambda-engine through a filter with time constants ZFLMSSL. Via bit 2 of the codeword CWSLS, one can select whether with transition from B_slsoff or B_sls flmssl from the PT1-filter output is switched hard to 0. | ||
− | <u>Secondary Air Adaption/Short Journey | + | <u>Secondary Air Adaption/Short Journey</u> |
The secondary air adaption via B_dslfa is requested from the secondary air diagnosis and switches on the secondary air for the time TDDSLA (B_sldsl4). It occurs in conjunction with the specification for lambda catalyst-heating then the secondary air mass adaptation or diagnosis in diagnostic phases 4, 5 (see also the description of the secondary air diagnosis in DSLSLR or DLSLRS). | The secondary air adaption via B_dslfa is requested from the secondary air diagnosis and switches on the secondary air for the time TDDSLA (B_sldsl4). It occurs in conjunction with the specification for lambda catalyst-heating then the secondary air mass adaptation or diagnosis in diagnostic phases 4, 5 (see also the description of the secondary air diagnosis in DSLSLR or DLSLRS). | ||
Line 134: | Line 134: | ||
Bit 1 = 0: secondary air with B_kh | Bit 1 = 0: secondary air with B_kh | ||
| | | | ||
− | Bit 1 = 1: no secondary air until vehicle speed | + | Bit 1 = 1: no secondary air until vehicle speed >= VSLS threshold |
|- | |- | ||
| | | | ||
Line 168: | Line 168: | ||
− | <u>Secondary Air Concept with Thermal | + | <u>Secondary Air Concept with Thermal Reaction in the Exhaust Manifold</u> |
CWSLS.0 = true. Secondary air already in the start in FTP-tmst region for quick start of post-reaction, Attention: On-board system load! | CWSLS.0 = true. Secondary air already in the start in FTP-tmst region for quick start of post-reaction, Attention: On-board system load! | ||
− | CWSLS.3 = true. Lambda exhaust set point | + | CWSLS.3 = true. Lambda exhaust set point --> automatic calculation of lambda-engine from secondary air dilution flamsl_w |
CWSLS.4 = true. Transition to lambda-engine when leaving idle, because post-reaction stops anyway | CWSLS.4 = true. Transition to lambda-engine when leaving idle, because post-reaction stops anyway | ||
Line 185: | Line 185: | ||
<u>Secondary Air Design with Further Reaction in the Catalyst</u> | <u>Secondary Air Design with Further Reaction in the Catalyst</u> | ||
− | CWSLS.0 = false: no secondary air in the | + | CWSLS.0 = false: no secondary air in the start |
CWSLS.1 = true/false depending on the start of partial light-offs in the catalyst (cat-position) | CWSLS.1 = true/false depending on the start of partial light-offs in the catalyst (cat-position) | ||
Line 341: | Line 341: | ||
0 sec | 0 sec | ||
| | | | ||
− | Secondary air valve closes at the same time as secondary air pump | + | Secondary air valve closes at the same time as secondary air pump control |
|- | |- | ||
| | | | ||
Line 383: | Line 383: | ||
FMSRHOL | FMSRHOL | ||
| | | | ||
− | overall factor = 1, | + | overall factor = 1, approximate without air density correction |
− | approximate without air density correction | + | |
|- | |- | ||
| | | | ||
Line 489: | Line 488: | ||
TLMSSLAB 1s Debounce time for detection of exit from idle | TLMSSLAB 1s Debounce time for detection of exit from idle | ||
− | ZFLMSSL 1s Time constant for transition from lambda-exhaust | + | ZFLMSSL 1s Time constant for transition from lambda-exhaust --> lambda-engine |
Line 503: | Line 502: | ||
TDSLKT: 10 s | TDSLKT: 10 s | ||
− | + | ||
+ | |||
<u>Abbreviations</u> | <u>Abbreviations</u> | ||
Latest revision as of 07:17, 28 December 2011
SLS88.150 Function Description
See the funktionsrahmen for the following diagrams:
sls-sls: Function overview
slson: Conditions for switching on secondary air
slsoff: Conditions for switching off secondary air
sls-slp: Conditions for setting the bits of SLP
sls-bmsl: Calculating the secondary air mass
sls-dichte: Calculating the air density correction factor for the secondary air mass
sls-bslpdyn: Description of the dynamic of the secondary air pump
sls-bslsoff: Description of the secondary air dynamic in the exhaust system
sls-bfmlssl: Calculation of enrichment due to secondary air
sls-bkt: Secondary air adaption/short journey
sls-e-slpe E_SLPE: error flag secondary air pump
sls-e-slve E_SLVE: error flag secondary air valve
sls-e-slpanst: Evaluation of the SLP-output stage
sls-slvanst: Evaluation of the SLV-output stage
sls-z-sls: Cycle flag: secondary air control (cylinder bank 1)
sls-z-sls2: Cycle flag: secondary air control (cylinder bank 2)
sls-init: Initialisation
sls-swoff: ECU delay
Function Description
Secondary air control is coordinated by the sub-function BBKHZ in overview module AK 1.10 and consists of the following sub-functions:
Switching Conditions:
The secondary air system is activated (i.e. B_SLS, B_SLV and B_SLP are all equal to 1) when B_kh = 1 and the imlpr-threshold IMLSLMN is crossed when the engine start temperature TMST lies in the window TMSSLU<tmst<TMSSLO and the intake air temperature tans is in the window TASLU<tans<TASLO. This allows the temperature range for switching on the secondary air system with respect to catalyst heating to be restricted, for example, secondary air pumps overheating or switching on to avoid a frozen secondary air system.
By setting bit 0 of the code word CWSLS, secondary air can already be enabled at start in the restricted temperature window TMSSLSTU<tmst<TMSSLST, for example in designs with thermal reactor, the self-ignition already ensured at engine start. However, the pre-condition is that this is voltage-slope compatible, i.e. the battery voltage is greater than UBSLSTMN.
Alternatively, by setting bit 1, the secondary air system can only be activated if the speed threshold VSLS is exceeded. This is common in secondary air designs in which the exothermic reaction is first ignited in the catalytic converter. Control of the secondary air pump relay is achieved by B_slp = 1 with the minimum holding time TSLPMN to prevent opening of the relay during pump starting current. Opening of the secondary air valve (B_slv = 1) can be delayed with respect to the pump by the time TVSLON. The secondary air valve is opened when B_sls = 1. For diagnostic purposes, the secondary air pump and the secondary air valve can be controlled additionally with the flags B_dspe, B_dslfa and B_dslp4.
In twin ECU designs, the secondary air valves or secondary air pumps are activated when it is detected by one of the two ECUs that conditions B_slp or B_slv are met. The two bits B_slp and B_sls are then fed
to each ECU over the CAN bus to ensure that the desired effects are initiated on both sides of the same arrangement.
Switch-off/termination Conditions
The secondary air is terminated
· When the threshold IMLSLMX is crossed (B_slpoff = 1)
· Via a debounce time TSLABB after the end of start conditions (B_stend = 1)
· When the maximum air mass threshold MLSLMX is crossed
· When the pressure difference DPSLV is too low to keep the vacuum-actuated secondary air valve open
· When the battery voltage is too low (UBSLMN)
· When there are output stage errors E_slpe, E_slve, or
· When the catalyst-heating termination condition is met (B_khab = 1).
The secondary air is not activated in the first place if:
· the output stage error has already been switched on
· A high electrical system voltage is detected (as UBSLMX) from a boost-start, a twin battery system or battery emergency power.
After switching off the secondary air pump, the secondary air valve can be closed after the time delay TVSLOFF. This is possibly required for engine designs in which the secondary air effects an improvement in fuel atomization in the combustion chamber. Closing the secondary air valve later can dampen the load-diminishing effect due to run-down of the secondary air pump. Caution: For designs with a valve check function for the secondary air diagnosis, a delayed switch-off of the secondary air valve is not acceptable, since the pump must work against the closed secondary air valve. After the power is switched off, the function to reinitialize secondary-air (C_ini) is blocked.
Description of the Secondary Air Mass
The secondary air mass msl is dependent on the electrical system voltage which is predetermined by the characteristic MSLUB and is corrected depending on the operating point from the map KFFMSML and the ambient air density (characteristic FMSRHOL). When the engine is hot, especially during adaptations- additional diagnostic phase, the secondary air mass can still be corrected depending on tmot by the characteristic FMSTMOT. The pump will run up and down described by the dynamic factor fslpdyn.
In twin cylinder bank designs (SY_STERVK) as well as twin-ECU designs (SY_2SG) with an exhaust bank per ECU (not SY_STERVK) and a single SLP (SY_SLPANZ = 1) and one exhaust bank each, the
secondary air system can be split in half and corrected on a bank-specific basis (FMSL, -2).
With bit 6 from the code word CWSLS (= B_slsadap), a secondary air adaptation factor fmsla(2) can be included as determined from the secondary air diagnosis. Finally, the secondary air dilution factor flamsl is calculated for the mixture control from the secondary air mass msl. After opening or closing the secondary air-valve, the dynamics of the secondary air flow into the exhaust are described by factor fmsldyn with the time constants ZKSLON and ZKSLOFF, after the air masses IMLSLSA, IMLSLSE were incorporated. The secondary air wash after closing the valve is indicated by B_slsoff.
Calculation of Enrichment due to Secondary Air
Bit 3 of the code word CWSLS determines whether there is lambda-engine set point during secondary air injection via map KFLMSKH from function LAKH (flmssl = 0) or whether there is lambda-exhaust set-point, including secondary air via map KFLASKH from function LAKH (flmssl = 1) from an automatic calculation of the required lambda-engine with consideration of the secondary air dilution factor flamsl. Designs with lambda-exhaust set point can also be dependent on bit 4 realized after leaving the debounced idle or inputting the driving phase (bit 5) of the transition to lambda-engine through a filter with time constants ZFLMSSL. Via bit 2 of the codeword CWSLS, one can select whether with transition from B_slsoff or B_sls flmssl from the PT1-filter output is switched hard to 0.
Secondary Air Adaption/Short Journey
The secondary air adaption via B_dslfa is requested from the secondary air diagnosis and switches on the secondary air for the time TDDSLA (B_sldsl4). It occurs in conjunction with the specification for lambda catalyst-heating then the secondary air mass adaptation or diagnosis in diagnostic phases 4, 5 (see also the description of the secondary air diagnosis in DSLSLR or DLSLRS).
The short journey is requested via B_fa and B_fasls when tmot > TMFASLMN and secondary air is activated for the time TDSLKT (B_slkt) when indicated by B_dslfa from module DSLSLR(S) via the diagnostics readiness. If catalyst heating is active, it remains so for the short test until the time TFALAMN and after that is disabled (since passive diagnostics are already running). Additionally, idle speed and torque reserve can be specified to set a diagnostics-capable engine operating point. This is especially necessary in conjunction with the diagnostic function DSLSLR for the two-point lambda control, by holding the engine under lambda = 1-control while the secondary air is not to operate at the rich limit.
It can be determined via CWFASL bit 2 whether the repeated incentives of short trips in a driving cycle is possible.
Application Notes
Suggested initial programming
Overview of the coding variants of code word CWSLS:
Bit 0 = 0: secondary air with B_kh |
Bit 0 = 1: secondary air at start already in engine temperature window |
Bit 1 = 0: secondary air with B_kh |
Bit 1 = 1: no secondary air until vehicle speed >= VSLS threshold |
Bit 2 = 0: select lambda-engine with B_sls TRUE. |
Bit 2 = 1: select lambda-engine with B_slsoff TRUE |
Bit 3 = 0: select lambda-engine |
Bit 3 = 1: select lambda-exhaust (= secondary air enrichment) |
Bit 4 = 0: lambda-set point the same as idle/part-load. |
Bit 4 = 1: transition to lambda-engine in part load |
Bit 5 = 0: lambda-set point the same as o/m drive. |
Bit 5 = 1: transition to lambda-engine with driving phase |
Bit 6 = 0. without secondary air adaptation |
Bit 6 = 1: with secondary air adaptation |
Bit 7 = 0: KFLASKH-set point with B_atmtpl (B_atmtpl enable secondary air enrichment) |
Bit 7 = 1: KFLASKH-set point without B_atmtpl, B_atmtpl is meaningless. (WARNING: only set for application phase!) |
Secondary Air Concept with Thermal Reaction in the Exhaust Manifold
CWSLS.0 = true. Secondary air already in the start in FTP-tmst region for quick start of post-reaction, Attention: On-board system load!
CWSLS.3 = true. Lambda exhaust set point --> automatic calculation of lambda-engine from secondary air dilution flamsl_w
CWSLS.4 = true. Transition to lambda-engine when leaving idle, because post-reaction stops anyway
CWSLS.5 = true. Transition to lambda-engine when loading the driving phase, because post-reaction stops anyway
CWSLS.6 = false. No secondary air adaptation
CWSLS.7 = false. KFLASKH set point only when B_atmtpl = true
Secondary Air Design with Further Reaction in the Catalyst
CWSLS.0 = false: no secondary air in the start
CWSLS.1 = true/false depending on the start of partial light-offs in the catalyst (cat-position)
CWSLS.3 = false: lambda engine set point during secondary air injection
CWSLS.6 = false: no secondary air adaptation
Overview of the coding variants of code word CWFASL:
Bit 0: 0: Short test termination if B_fs, vfzg> 0 or B_brems / B_kuppl (see bit 1). 1: no short test termination via B_fs, or vfzg B_brems/B_kuppl possible.
Bit 1: 0: Short test termination if B_brems or B_kuppl. 1: brake and clutch have to be actuated for a short test.
Bit 2: 0: short test can be induced only once in the driving cycle. 1: Short test times can be induced (see bit 3).
Bit 3: 0: Short test only possible after deleting previous fault memory. 1: short test possible without deleting error memory.
WARNING: When bit 3 is set, there is a risk that the catalyst is superheated by repeatedly carrying out short tests.
SLS parameters:
IMLSLMN |
0 |
Secondary air at the same time as B_kh |
IMLSLMX |
0.9961 |
Secondary air during entire catalyst heating |
TMSSLSTU |
15°C |
Secondary air from tmst > 15°C is already at the start CWSLS.0 = true |
TMSSLSTO |
35°C |
Secondary air from tmst < 35°C |
TMSSLU |
15°C |
Secondary air with B_kh when tmst > 15°C |
TMSSLO |
35°C |
Secondary air with B_kh when tmst < 35°C |
TASLSU |
15°C |
Secondary air with B_kh when tans > 15°C |
TASLSO |
35°C |
Secondary air with B_kh when tans < 35°C |
VSLS |
10 km/h |
Secondary air only when vehicle speed > 10 km/h when CWSLS.1 = true |
MLSLMX |
200 kg/h |
Termination threshold when ml > 200 kg/h |
DPSLV |
0 mbar |
Termination threshold pressure difference to open the secondary air valve |
UBSLMN |
9 V |
Minimum battery voltage for sufficient secondary air mass |
TSLABB |
1 sec |
Debounce time for secondary air termination after engine start (B_stend) |
UBSLMX |
16 V |
Fan protection during boost start |
UBSLSTMN |
8 V |
B_sls at start when battery voltage > 8 V |
TSLUBST |
2 sec |
Debounce time for battery voltage at start |
Secondary air pump parameters
TVSLVON |
0.1 sec |
Secondary air valve opened at the same time as secondary air pump control |
TVSLVOFF |
0 sec |
Secondary air valve closes at the same time as secondary air pump control |
TVDSLOFF |
2 sec |
Secondary air valve closes 2 seconds after short journey/adaptation |
TSLPMN |
500 ms |
Minimum dwell time of the secondary air pump-relay to the relay protection |
TVSLP2 |
2 sec |
Delay time for triggering a second secondary air pump |
BMSL parameters:
MSLUB = |
Function of battery voltage. Obtained from laboratory measurements of the fan at 100 mbar back pressure, check the details required in the vehicle! |
KFFMSML = |
Function of engine speed and relative load |
FMSRHOL |
overall factor = 1, approximate without air density correction |
FMSTMOT = |
Function of engine temperature overall = 1, approximate without correction |
FMSL,-2 |
1 no single bank correction |
BSLPDYN parameters:
ZKSLPON |
1s |
Fan run-up |
ZKSLPOFF |
1s |
Fan run-down |
BSLSOFF parameters
IMLSLA |
3.5 g |
|
IMLSLSE |
3.0 g |
Implementing air mass to clean out the secondary air system |
Dynamic SLP:
Dependent on ml: |
20 |
40 |
60 |
100 |
kg/h |
ZKSLSONML 0.5 s |
1.5 s |
1.0 s |
0.5 s |
0.2 s |
Project specific |
ZKSLSOFML 0.5 s |
1.5 s |
1.0 s |
0.5 s |
0.2 s |
Project specific |
BFMLSSL parameters
TLMSSLMX 60 s Termination of the thermal reaction (lambda-exhaust set point) after 60 s at idle
TLMSSLAB 1s Debounce time for detection of exit from idle
ZFLMSSL 1s Time constant for transition from lambda-exhaust --> lambda-engine
BKT parameters:
CWFASL s. o
TMFASLMN: 60°C
TFASLAMN: 60 sec
TDDSLA: 25 s
TDSLKT: 10 s
Abbreviations
Parameter |
Description |
CONT |
|
CWFASL |
Code word: calibrator intervention for secondary air diagnostics |
CWSLS |
Code word for secondary air system |
DPSLV |
Minimum pressure difference across the secondary air valve |
FMSL |
Factor for correcting secondary air mass, cylinder bank 1 |
FMSL2 |
Factor for correcting secondary air mass, cylinder bank 2 |
FMSLOFF |
Clearing threshold of the secondary air terminated |
FMSRHOL |
Air density correction of the secondary air mass |
FMSTMOT |
Engine speed correction of the secondary air mass |
IMLSLMN |
Minimum ratio factor psum_w/mlsu for switching on SLS |
IMLSLMX |
Maximum ratio factor psum_w/mlsu for switching on SLS |
IMLSLSA |
Air mass integral threshold for initiation of secondary air in exhaust |
IMLSLSE |
Air mass integral threshold for termination of secondary air in exhaust |
KFFMSML |
Exhaust back-pressure corrections of the secondary air mass |
MLSLMX |
Maximum engine-air mass for secondary air injection |
MSLUB |
Secondary air mass dependent on the battery voltage |
SY_BATTSG |
System constant: twin battery design |
SY_SGANZ |
System constant: number of ECUs |
SY_SLPANST |
System constant: activation of the secondary air pump with twin-ECU, 0 = master, 1 = slave, 2 = master & slave. Seperate |
SY SLPANZ |
System constant for the number of secondary air pumps |
SY_SLVANST |
System constant: activation of the secondary air valve with twin-ECU, 0 = master, 1 = slave, 2 = master & slave. Seperate |
SY_SLWG |
System constant condition flag: secondary air/turbo wastegate present |
SY_STERVK |
System constant condition flag: stereo lambda control before catalytic converter |
TASLSO |
Upper air intake temperature threshold for secondary air system |
TASLSU |
Under air intake temperature threshold for secondary air system |
TDDSLA |
Continuous secondary air injection for adaptation phase |
TDSLKT |
Continuous short test secondary air diagnose for mass measurement |
TFASLAMN |
Minimum catalyst heating time for test requirement in secondary air diagnostics |
TLMSSLAB |
Debounce time for terminating secondary air enrichment |
TLMSSLMX |
Maximum time for secondary air enrichment during idle |
TMFASLMN |
Engine temperature threshold test requirement for secondary air diagnostics |
TMSSLO |
Upper start temperature threshold for secondary air |
TMSSLSTO |
Upper temperature threshold for secondary air at start |
TMSSLSTU |
Lower temperature threshold for secondary air at start |
TMSSLU |
Lower start temperature threshold for secondary air |
TSLABB |
Delay time for secondary air – termination condition |
TSLPMN |
Minimum duty cycle of the secondary air pump |
TSLUBST |
Debounce time for secondary air on at start by UBSLSTMN |
TVDSLOFF |
Time delay for closing secondary air valve for adaptation/short journey |
TVSLP2 |
Time delay for control of the no. 2 secondary air pump |
TVSLVOFF |
Time delay on closing the secondary air valve |
TVSLVON |
Time delay on opening the secondary air valve |
UBSLMN |
Minimum voltage for secondary air on |
UBSLMX |
Maximum voltage for secondary air on |
UBSLSTMN |
Minimum voltage for secondary air on at start |
VSLS |
Vehicle speed threshold for secondary air control on |
ZFLMSSL |
Time constant: mixture part secondary air |
ZKSLPOFF |
Time constant: secondary air fan off/low flow |
ZKSLPON |
Time constant: secondary air fan on/run-up |
ZKSLSOFML |
Time constant: evacuation of the secondary air after valve shut |
ZKSLSONML |
Time constant: introduction of secondary air after valve open |
Variable |
Description |
B_ATMTPL |
Condition flag: dew point after catalyst exceeded (last journey) |
B_BATNOT |
Condition flag: battery emergency start with twin battery design |
B_BREMS |
Condition flag: brake operated |
B_DSLFA |
Condition flag: secondary air system requirement for short test |
B_DSLRESET |
Condition flag: reset secondary air adaptation/short test |
B_DSLSET |
Condition flag: set secondary air adaption/short test |
B_DSLSP4 |
Condition flag: secondary air system requirement for secondary air adaption/additional diagnostics |
B_DSPE |
Condition flag: diagnostic secondary air on |
B_DWG |
Condition flag: wastegate diagnostics |
B_ESLPE_C |
Condition flag: error secondary air pump (output stage) sent via CAN |
B_ESLVE_C |
Condition flag: error secondary air valve (output stage) sent via CAN |
B_FA |
Condition flag: general functional requirement |
B_FASLA |
Condition flag: external request to activate secondary air system |
B_FASLS |
Condition flag: function requirement secondary air system |
B_FS |
Condition flag: driving phase |
B_KH |
Condition flag: catalyst heating |
B_KHA |
Condition flag: catalyst-heating requirement |
B_KHAB |
Condition flag: catalyst-heating terminated |
B_KUPPL |
Condition flag: clutch actuated |
B_LL |
Condition flag: idle |
B_LMSSLOF |
Condition flag: lambda-engine-set point-secondary air part, off |
B_MASTERHW |
Condition flag: master-ECU in accordance coding pins (plausibility check) |
B_MSLMN |
Condition flag: insufficient secondary air mass |
B_MSLOFF |
Condition flag: secondary air mass ausgeräumt after secondary air phase |
B_MSLON |
Condition flag: steady-state secondary air mass after start of the secondary air |
B_NMOT |
Condition flag: engine speed > NMIN |
B_SLDSL4 |
Condition flag: enabling secondary air for diagnostics phase 4 |
B_SLKHOF |
Condition flag: switching off the secondary air pump via imlpr-threshold |
B_SLKT |
Condition flag: enabling secondary air for short test |
B_SLP |
Condition flag: secondary air pump No. 1 |
B_SLP2 |
Condition flag: secondary air pump No. 2 |
B_SLPANST |
Condition flag: for evaluation of the output stage error in secondary air control function |
B_SLPENA |
Condition flag: switching on the secondary air pump |
B_SLPMN |
Condition flag: minimum operating time of the secondary air pump |
B_SLPOFF |
Condition flag: secondary air pump switched off |
B_SLPOFST |
Condition flag for setting flip-flop B_slpoff |
B_SLPT |
Condition flag for secondary air pump, temporary intermediate size |
B_SLP_C |
Condition flag for secondary air pump, sent via CAN |
B_SLS |
Condition flag: secondary air active |
B_SLSADAP |
Condition flag: secondary air mass adaptation |
B_SLSDIS |
Condition flag for switching off the secondary air pump |
B_SLSERR |
Condition flag for blocking activation of the secondary air pump |
B_SLSFZ |
Condition flag: secondary air system installed in the vehicle |
B_SLSINHI |
Condition flag: blocked by setting bit B_sls |
B_SLSOAB |
Condition flag: secondary air system without implementing the termination criterion |
B_SLSOFF |
Condition flag: secondary air injection terminated after elimination of the secondary air |
B_SLST |
Condition flag: secondary air active, temporary intermediate size |
B_SLS_C |
Condition flag: secondary air active sent via CAN |
B_SLV |
Condition flag for secondary air valve |
B_SLVANST |
Condition flag for determining the output stage error in the secondary air control module |
B_ST |
Condition flag: start |
B_STEND |
Condition flag: end of start conditions reached |
DFP_SLPE |
Internal error path number: secondary air pump output stage |
DFP_SLS |
Internal error path number: secondary air system (cylinder bank 1) |
DFP_SLS2 |
Internal error path number: secondary air system (cylinder bank 2) |
DFP SLVE |
Internal error path number: secondary air valve output stage |
E_SLPE |
Error flag: secondary air pump (output stage) |
E_SLVE |
Error flag: secondary air valve (output stage) |
FLAMSL_W |
Factor for lambda adjustment through secondary air (cylinder bank 1) |
FLAMSL2_W |
Factor for lambda adjustment through secondary air, (cylinder bank 2) |
FLMSSL |
Factor lambda-engine-set point secondary air part |
FMSAGD |
Exhaust gas back-pressure correction factor for the secondary air mass |
FMSLA |
Correction factor secondary air mass adaptive (cylinder bank 1) |
FMSLA2 |
Correction factor secondary air mass adaptive (cylinder bank 2) |
FMSLDYN |
Factor for dynamic specification of secondary air |
FMSLKOR |
Factor to correct the secondary air mass |
FMSLRHO |
Air density correction of the secondary air mass |
FMSLTM |
Engine temperature correction of the secondary air mass |
FRHOKOR_W |
Factor to address the air density correction of the secondary air |
FSLPDYN |
Factor for dynamic specification of the secondary air pump |
IMLPR |
Relative air mass integral during catalyst heating |
IMLSLA_W |
Air mass integral for introducing the secondary air |
IMLSLE_W |
Air mass integral for end of secondary air in exhaust |
MLBB_W |
Air mass flow filtered (word), cylinder bank 1 |
MLBB2_W |
Air mass flow filtered (word), cylinder bank 2 |
ML_W |
Air mass flow filtered (word) |
MSL |
Secondary air mass flow (cylinder bank 1) |
MSL2 |
Secondary air mass (cylinder bank 2) |
MSL2_W |
Secondary air mass (cylinder bank 2) 16-Bit value |
MSLKORR_W |
Corrected secondary air mass flow with consideration of pump dynamics (bank 1) |
MSLPUB_W |
Secondary air mass flow (battery voltage dependent) 16-Bit |
MSLSTAT |
Static secondary air mass flow |
MSLSTAT_W |
Static secondary air mass flow, 16-Bit |
MSL_W |
Secondary air mass flow 16-Bit value |
NMOT |
Engine speed |
PS_W |
Intake absolute pressure (word) |
PU |
Ambient pressure |
RL |
Relative air charge |
TANS |
Ambient air temperature |
TMOT |
Engine temperature |
TMST |
Engine start temperature |
TNST_W |
Time after end of start |
UBSQF_W |
System voltage, converted into standard quantization and filtered |
VERHMSB_W |
Number of the cylinder-specific mass flow distribution factor for cylinder bank 1 |
VERHMSB2_W |
Number of the cylinder-specific mass flow distribution factor for cylinder bank 2 |
VFZG |
Vehicle speed |
Z_SLS |
Cycle flag: secondary air-system (cylinder bank 1) |
Z_SLS2 |
Cycle flag: secondary air-system (cylinder bank 2) |