MDFUE 8.50 (Setpoint for Air Mass from Load Torque)

From Nefmoto

Revision as of 03:53, 25 December 2011 by TTQS (Talk | contribs)

Jump to: navigation, search

MDFUE 8.50 Function Description

See the funktionsrahmen for diagram mdfue.


The torque variable milsol_w, which is set on the charge path at the basic ignition angle and basic efficiency is converted into torque variable misopl1_w, which corresponds to the optimum torque at lambda = 1. The map KFMIRL provides the cylinder charge which corresponds to this operating point.


This cylinder charge is limited to a minimum permitted value rlmin_w at which the condition B_mdmin is set for idle control which then stops the integrator. In the case of a turbocharger, there is a limit on the maximum permitted cylinder charge rlmax_w. This variable does not exist for naturally-aspirated engines!


The result is the desired cylinder charge rlsol_w.


Supplement to the application interface:

CWRLAPPL = 0: Function as before: rlsol generated from the limited KFMIRL.

CWRLAPPL bit 1 =1: rlsol_w = RLSOLAP

CWRLAPPL bit 2 =1: rlsol_w = wped_w x FWPEDRLS


Application Notes

The map KFMIRL is the inverse of map KFMIOP in the function MDBAS (it is understood that this is not a direct arithmetic inverse, but is intended to mean that the functions on the x, y & z axes are complementary). See MDBAS for application notes.

Parameter

Description

CWRLAPPL

Code word: default rlsol_w during applications phase

FRLMNHO

Correction factor for rlmin via altitude

FWPEDRLS

Factor for direct entry to the default rlsol from wped (application)

KFMIRL

Map for calculating target cylinder charge

KFRLMN

Minimum cylinder charge in firing mode

KFRLMNSA

Minimum rl during overrun fuel cut-off

RLSOLAP

Target cylinder charge for application calibration purposes

ZKDRLSOL

Time constant for drlsol-integrator

Variable

Description

B_MDMIN

Condition flag: minimum achievable indexed torque reached

B_SA

Condition flag: overrun fuel cut-off active

C_INI

ECU initialisation condition

DRLSOLF_W

Filtered change in target cylinder charge

DRLSOL_W

Change in target cylinder charge

ETALAB

Lambda efficiency without intervention with respect to the optimum torque at lambda = 1

ETAZWBM

Average ignition angle efficiency at the basic ignition angles

FHO

Altitude correction factor

MILSOL_W

Driver’s requested torque for cylinder charge path

MISOPL1_W

Target air torque, back-calculated from lambda = 1 and zwopt

NMOT

Engine speed

NMOT_W

Engine speed (word)

RLMAX_W

Maximum achievable cylinder charge from the turbo

RLMIN_W

Minimum permitted rl

RLSOL_W

Target cylinder charger

RLTEDTE_W

Relative cylinder charge from the fuel tank breather valve determined from DTEV

R_T10

Time graticule of 10 ms

SY_TURBO

System constant: turbocharger

TMOT

Engine temperature

WPED W

Normalised throttle pedal angle

Personal tools