ME9 Abbreviations in English (G-L)
From Nefmoto
GAFGRO |
max. permitted gear during active cruise control |
GAFGRU |
min. permitted gear during cruise control is active |
GANGNWLLPA |
Gear: application value exhaust camshaft at idle |
GAP_TOOTH |
SW benchmark gap difference in teeth |
GFDLDN |
LLR: weightning factor for D-amplification on the air path |
GKC_T_UC |
Time for fault detecting in Mixture monitoring in Instruction test |
GKC_T_UM |
verification time for fuel adaption at monitoring function |
GKTEDKX05 |
max. compensation gradient for smallest leak detection (0.5-mm-check) |
GMBPV_T_UM |
Fault debouncing: fault in brake message protection value GMLan |
GMBSH_T_UM |
Fault debouncing: rolling counter halted, GMLan |
GMBSS_T_UM |
Fault debouncing: rolling counter messages skipped, GMLan |
GMDSBMX_UM |
Maximum deviation of rollingcounter for brake message GMLan |
HACOEF0 |
Coefficient zero degree for calculation of transha_w |
HACOEF1 |
Coefficient first degree for calculation of transha_w |
HACOEF2 |
Coefficient second degree for calculation of transha_w |
HDEVBC0 |
HPIV output-stage booster cycle parameter record0 |
HDEVBC2 |
HPIV output-stage booster cycle parameter record2 |
HDEVBCC0 |
HPIV output-stage booster current control 0 |
HDEVBCC1 |
HPIV output-stage booster current control 1 |
HDEVBCC2 |
HPIV output-stage booster current control parameter record2 |
HDEVBDT |
HPIV output-stage booster delay time |
HDEVBPT0 |
HPIV output-stage booster phase timeout parameter record0 |
HDEVBPT1 |
HPIV output-stage booster phase timeout parameter record1 |
HDEVBPT2 |
HPIV output-stage booster phase timeout parameter record2 |
HDEVDCCCLL0 |
|
HDEVDCCCLL1 |
|
HDEVDCCCLL2 |
|
HDEVDCCCUL0 |
|
HDEVDCCCUL1 |
|
HDEVDCCCUL2 |
|
HDEVDCEN1 |
HPIV output-stage enable DC/DC converter (first CJ840_1) |
HDEVDCEN2 |
HPIV output-stage enable DC/DC converter (second CJ840_2) |
HDEVDCTM1 |
HPIV output-stage DC/DC converter toggle mode (first CJ840_1) |
HDEVDCTM2 |
HPIV output-stage DC/DC converter toggle mode (second CJ840_2) |
HDEVENLS1 |
HPIV output-stage enable lowside switches 1...4 (first CJ840_1) |
HDEVENLS2 |
HPIV output-stage enable lowside switches 1...4 (second CJ840_2) |
HDEVFCLK |
HPIV output-stage frequency at pin CLK |
HDEVHC |
HPIV output-stage hysteresis current |
HDEVHCC0 |
HPIV output-stage hold current control parameter record0 |
HDEVHCC1 |
HPIV output-stage hold current control parameter record1 |
HDEVHCC2 |
HPIV output-stage hold current control parameter record2 |
HDEVMSV1 |
HPIV output-stage MSV mode (first CJ840_1) |
HDEVMSV2 |
HPIV output-stage MSV mode (second CJ840_2) |
HDEVPUCC |
HPIV output-stage pick up current control |
HDEVPUP0 |
HPIV output-stage pick up phase 0 |
HDEVPUP1 |
HPIV output-stage pick up phase 1 |
HDEVPUP2 |
|
HEALINT |
Length of healing interval in revolutions CrS |
HPUTEDU |
lower pressure threshold for performing of the 0.5mm tank leak diagnosis |
HPUTEDU |
lower pressure threshold for performing of the 0.5mm tank leak diagnosis |
HYNMOTNW |
Hysteresis f. nmot_w f. characteristic map addressing |
HYNWNMOT |
Camshaft Speed hysteresis for the avoidance of nmot fluctuations |
HYRLNW |
hysteresis of rlnw to adress map |
IAAAAA |
Dummy fid: Initial Active Counter (Mode A) |
IAAAAA |
Dummy fid: Initial Active Counter (Mode A) |
IAAFRA |
Initial Active Counter: Mode A, range FRA of LRA |
IAAFRAT |
|
IAAORA |
Initial Active Counter: Mode A, range ORA of LRA |
IAATEH |
Initial Active Counter: Mode A, purge control at high load |
IAATEL |
Initial Active Counter: Mode A, purge control at low load |
IAATEN |
active-time switches to prio. limit LHATEN (emergency canister purge) |
IAATLDI |
|
IAATLDO |
|
IABAAA |
Dummy fid: Initial Active Counter (Mode B) |
IABDLSU |
|
IABFRST |
Initial Active Counter: Mode B, short test of close loop control |
IABHKT |
Demanded Active-time of function DKATSP |
IABHKT2 |
Demanded Active-time of function DKATSP |
IABLASH |
Initial Active Counter: Mode B, function DLSAHK |
IABLLRH |
active-time switches to prio. limit LHBLLRH (idlespeed deviation HOM) |
IABLLRKH |
active-time switches to prio. limit LHBLLRKH of idle speed control diagnosis |
IABPLSU |
|
IACAAA |
|
IDTHMU |
lower threshold of integrated airmass for enabling thermostat diagnostics |
IEFFCOEF0 |
coefficient to calculate the ineffeciency of the transmission |
IEFFCOEF1 |
coefficient to calculate the ineffeciency of the transmission |
IEFFCOEF2 |
coefficient to calculate the ineffeciency of the transmission |
IEFFCOEF3 |
exponential coefficient to calculate the ineffeciency of the transmission |
IEFFTRADEF |
Default value for the transmission ineffeciency |
IGESGA |
Total transmission ratio |
IGNOFFTMRSTRT |
|
IIAAAA |
Dummy fid: Initial Inactive Counter (Mode A) |
IIAAAA |
Dummy fid: Initial Inactive Counter (Mode A) |
IIAFRA |
Initial inactive Counter: Mode A, range FRA of LRA |
IIAFRAT |
|
IIAORA |
Initial inactive Counter: Mode A, range ORA of LRA |
IIATEH |
Initial Inactive Counter: Mode A, purge control at high load |
IIATEL |
Initial Inactive Counter: Mode A, purge control at low load |
IIATEN |
inactive-time switches to prio. limit LHATEN (emergency canister purge) |
IIATLDI |
|
IIATLDO |
|
IIBAAA |
Dummy fid: Initial Inactive Counter (Mode B) |
IIBDLSU |
|
IIBFRST |
Initial Inactive Counter: Mode B, short test of close loop control |
IIBHKT |
Accepted Inactive-time of function DKATSP |
IIBHKT2 |
Accepted Inactive-time of function DKATSP |
IIBLASH |
Initial Inactive Counter: Mode B, function DLSAHK |
IIBLLRH |
inactive-time switches to prio. limit LHBLLRH (idlespeed deviation HOM) |
IIBLLRKH |
inactive-time switches to prio. limit LHBLLRKH of idle speed control diagnosis |
IIBPLSU |
|
IICAAA |
|
IIGCURRENT |
configuration current value ignition driver |
ILALIUSHK |
Inverse LALIUSHK |
ILMLKAXTK |
Threshold of richness area of O2 purging after fuel cat off, funct. of cat-temp |
IMDTMHSU |
Lower threshold value for imlatm (tmhsrc enabling of the operating range) |
IMG_BDLSU |
IUMPR-group of oxygen sensor bank1 |
IMG_BHKT |
IUMPR-group of catalyst monitor |
IMG_BLASH |
IUMPR-group of DLSAHK bank1 |
IMG_BLLRH |
IUMPR-group of idle speed monitor |
IMG_BLLRKH |
IUMPR-group of idle speed monitor during catalyst heating |
IMG_CANWS |
IUMPR-group of residual gas control exhaust camshaft |
IMG_CBKVP |
IUMPR-group of brake booster pumpt |
IMG_CDEONV |
IUMPR-group of EONV 0.5mm (0.02"") |
IMG_CDSTD |
IUMPR-group of tank pressure sensor (drift) |
IMG_CDSTR |
IUMPR-group of tank pressure sensor (plausibility check) |
IMG_CDVEL |
IUMPR for position fault throttle valve |
IMG_CDVER |
IUMPR for controller range throttle valve |
IMG_CDWVA |
IUMPR-group for angle misalignment detection outlet camshaft bank 1 |
IMG_CDWVE |
IUMPR-group for angle misalignment detection inlet camshaft bank 1 |
IMG_CDYSH |
IUMPR-group of DDYLSH bank1 |
IMG_CENWS |
IUMPR-group of residual gas control inlet camshaft |
IMG_CFST |
In use Monitoring Group: diagnostics tank fuel level |
IMG_CHFMR |
IUMPR-group of HFM-rationality-monitor |
IMG_CHSHK |
IUMPR-group of heater rear sensor |
IMG_CHSV |
IUMPR-Group of oxygen monitor |
IMG_CNWVA |
IUMPR-group of residual gas control exhaust camshaft |
IMG_CNWVE |
IUMPR-group of residual gas control inlet camshaft |
IMG_CPBKVR |
IUMPR-group of pressure sensor of brake booster |
IMG_CPLSU |
IUMPR group of plausibility check of LSU |
IMG_CPSRR |
IUMPR-group of PSR-rationality-monitor |
IMG_CPUR |
IUMPR-group of PU-rationality-monitor |
IMG_CPVDR |
IUMPR-group of PVD-rationality-monitor |
IMG_CSUVRH |
IUMPR-group of MAF-based dump valve diagnosis |
IMG_CSUVRP |
IUMPR-group of pressure-based dump valve diagnosis |
IMG_CTABSS |
TABSS configuration of the IUMPR connection |
IMG_CTACS |
configuration IUMPR-counter for E_TACS |
IMG_CTAHCS |
configuration IUMPR-counter for E_TAHCS |
IMG_CTAHR |
configuration IUMPR-counter for E_TAHR |
IMG_CTAR |
configuration IUMPR-counter for E_TAR |
IMG_CTES |
IUMPR-group of fuel purge system |
IMG_CTESG |
IUMPR-Group of tank leak test (rough leak) |
IMG_CTH |
DTHM configuration of IUMPR connection |
IMG_CTM |
TMOT configuration of the IUMPR connection |
IMG_CTMCS |
configuration IUMPR-counter for E_TMCS |
IMG_CULSU |
IUMPR-Group of oxygen monitor |
IMG_CVFZ |
IUMPR group for speed diagnosis |
IMKDKVSF |
fuel mass threshold for error enable in DKVS (empty tank) |
IMKDKVSG |
fuel mass threshold for error enable empty tank |
IMKKVSMX |
maximum integration threshold for error enabled in DKVS (empty tank) |
IMLEVABS |
Threshold air mass integral before lambda control enable after cylinder cut-off |
IMLHS |
integrated flow of air-mass at hot start |
IMLKAMN |
integrated air mass threshold for minimum duration of cat oxygen neutralization |
IMLKAOSCMX |
integrated air mass threshold for quick pass value valid |
IMLKS |
threshold integrated air mass for detection fuel in oil |
IMLNAMN |
minimum integrated air flow mass for not active check |
IMLSALR |
thresh.value integr.air mass for activ.delay of lambda contr.after fuel cut-off |
IMLTM |
min. imlatm for TMOT diagnosis (low temperatures) |
IMMOEXPORT |
|
IMMO_CNF |
|
IMPDNCAL |
Calibration Value of Denominator |
IMPGDCAL |
Calibration Value of General Denominator |
IMPICCAL |
Calibration Value of Ignition |
IMPNMCAL |
Calibration Value of Numerator |
IMSABGMX |
inverse value für maximum possible exhaust gas flow |
IMSRTENL |
Threshold reset intregral purge mass flow for open loop fuel purge |
IMSTEFVMN |
Threshold minimum purge rate for error suspicion fuel purge control |
IMSTEMNTLD |
min. integral of purge mass flow for TLD |
IMTUMTA |
threshold integrated air mass for determination ambient temperature |
INCKSTAI |
increment-step for STADAP factor |
IPREFLSUB |
|
IPREFLSUE |
|
IPSNWOT_UC |
Threshold for detection of WOT in level 2 monitoring in instruction test |
IPSNWOT_UM |
Threshold for detection of WOT in level 2 monitoring |
IRAAAA |
Dummy fid: Initial value of ramp priority, mode A |
IRAAAA |
Dummy fid: Initial value of ramp priority, mode A |
IRAFRA |
initial value of ramp priority: Mode A, range FRA of LRA |
IRAFRAT |
|
IRAORA |
initial value of ramp priority: Mode A, range ORA of LRA |
IRATEH |
init value of ramp priority: Mode A, purge control at high load |
IRATEL |
init value of ramp priority: Mode A, purge control at low load |
IRATEN |
initial value of ramp priority RPRATEN of emergency canister purge |
IRATLDI |
|
IRATLDO |
|
IRBAAA |
Dummy fid: Initial value of ramp priority, mode B |
IRBDLSU |
|
IRBFRST |
initial value of ramp priority: Mode B, short test of close loop control |
IRBHKT |
Initial value of ramp priority RPR of DKATSP |
IRBHKT2 |
Initial value of ramp priority RPR of DKATSP |
IRBLASH |
init value of ramp priority: Mode B, function DLSAHK |
IRBLLRH |
initial value of ramp priority RPRBLLRH of idlespeed deviation HOM |
IRBLLRKH |
initial value of ramp priority rprbllrkh of idle speed control diagnosis |
IRBPLSU |
|
IRCAAA |
Dummy fid: Initial value of ramp priority, mode C |
ISDLAHOF |
high integration speed for dlaho calculation |
ISDLAHOF |
high integration speed for dlaho calculation |
ISDLAHOL |
normal integration speed for dlaho calculation |
ITNMXH |
Dwell time below lower engine speed limit before activation of upper limit |
IVDYNLSU |
input value for dynlsu_w |
JAAAAA |
Dummy fid: Jump in priority at activation (Mode A) |
JAAAAA |
Dummy fid: Jump in priority at activation (Mode A) |
JAAFRA |
Jump in priority at activation: Mode A, range FRA of LRA |
JAAFRAT |
|
JAAORA |
Jump in priority at activation: Mode A, range ORA of LRA |
JAATEH |
Jump in priority at activation: Mode A, purge control at high load |
JAATEL |
Jump in priority at activation: Mode A, purge control at low load |
JAATEN |
priority offset of emergency canister purge while active |
JAATLDI |
|
JAATLDO |
|
JABAAA |
Dummy fid: Jump in priority at activation (Mode B) |
JABDLSU |
|
JABFRST |
Jump in priority at activation: Mode B, short test of close loop control |
JABHKT |
Priority offset of DKATSP while active |
JABHKT2 |
Priority offset of DKATSP while active |
JABLASH |
jump in priority at activation: Mode B, function DLSAHK |
JABLLRH |
priority offset of idlespeed deviation HOM while active |
JABLLRKH |
priority offset of idle speed control diagnosis while active |
JABPLSU |
|
JACAAA |
Dummy fid: Jump in priority at activation (Mode C) |
JMOTOR |
moment of inertia of combustion engine scaled with MDNORM |
KAFPBKVPU |
correction discharge depending on pbkvmod_w/pubkv_w |
KAMFZ |
start of sampling segment time monitoring misfire detection |
KAMFZKH |
start of sampling segment time monitoring misfire detection at catalyst heating |
KAPDGLNGTH |
length of KAP-diagnosis given in incremets |
KAPDIAGTOL |
tolerance of KAP-diagnosis |
KAPINCDGDF |
default start value of KAP-diagnosis |
KAPINCRDEF |
default value of KAP-timer |
KAPMAXTIME |
Maximum value of ECU-off-timer |
KAPMAXTIME |
Maximum value of ECU-off-timer |
KAPSECPINC |
Seconds per increment within KAP-timer |
KAPSYNCMAX |
maximum number of synchronisation trials till error entry |
KATMCPAV |
Absolute heat capacity exhaust valve = cp_Krümmer*mass of manifold |
KATMCPHK |
Abs. heat capacity at tube in front of main cat=cp_Rohr*mass of tube at main cat |
KATMCPHX |
Absolute heat capacity at manifold = cp_Krümmer*mass of hexagon |
KATMCPKR |
Absolute heat capacity at manifold = cp_Krümmer*mass of manifold |
KATMCPNHK |
Absolute heat capacity at tube downstreamf pre-catalyst = cp_Rohr*mass of tube |
KATMCPNVK |
absolute heat capacity tube downstream of precatalyst= cp_tube*tube mass |
KATMCPRO |
Absolute heat capacity of pipe = cp_pipe*mass of pipe |
KATMCPVK |
Absolute heat capacity at tube in front of pre-catalyst = cp_Rohr*mass of tube |
KATMCPVY |
Abs. heat capacity at tube in front of Y=cp_Rohr*mass of tube at Y |
KDHRLSU |
D boosting factor of PID controller for %HRLSU |
KDLAMLASHM |
Delta Lambda set point (lean) for the shorttrip-test oscillation check downstrea |
KDLSHKMI |
evaluation factor of I-part of LRHKC, f(dlshkmi) |
KDLSHKMP |
evaluation factor of P-part of LRHKC, f(dlshkmp) |
KDYNFA |
Recursion constant for LSU dynamics at funktion request |
KDYNLSU |
Recursion constant for LSU dynamics |
KDZLSU |
Discrete filter constant for dzlsuu_w |
KEMLN |
length of the sampling window for knock control |
KFAMAL |
map reduction factor of the engine roughness reference value at multiple misfire |
KFAMAL1 |
map reduction factor of the engine roughness reference value at multiple misfire |
KFAMAL2 |
map reduction factor of the engine roughness reference value at multiple misfire |
KFANFHOMKH |
Downscaling factor for catalyst heating requrirements at hom. single injection |
KFATLAMS |
map correction of lambda for gas temperature in exhaust manifold |
KFATMKRH |
Map for steady-state temperature at manifold at homogeneous operation |
KFATMKRH |
Map for steady-state temperature at manifold at homogeneous operation |
KFATMKRS |
Map for steady-state temperature at manifold at shift operation |
KFATZWMS |
map correction of ignition angle for gas temperature in exhaust manifold |
KFBADE |
factor accel. enrichment direct injection |
KFBRAWA |
Target acceleration for resumption |
KFBS_UC |
bank-specific mixture correction in instruction test |
KFBS_UM |
bank-specific mixture correction in function monitoring |
KFCFO1 |
map for definition of range characteristics (dominant..) |
KFCFO2 |
map for definition of range characteristics (dominant..) |
KFDIPQHOM |
Characteristic map homogeneous mode |
KFDLAQHOM |
lambdamap in homogeneous mode |
KFDLASO |
Char. map corr. of the lambda setpoint value for the cont. lambda controller |
KFDLATRNL |
desired delta lambda of exhaust temperature control substitution |
KFDLSD |
Damping of PT2 filter in positive torque slope limitation |
KFDLUR |
map engine roughness difference dluts referenz value |
KFDLUR1 |
map engine roughness difference dluts referenz value |
KFDLUR2 |
map engine roughness difference dluts referenz value |
KFDMDADP |
upper threshold for torque-intervention during dashpot |
KFDMDARO |
Upper threshold for torque intervension |
KFDMDAROS |
upper threshold for torque-intervention at steady-state |
KFDMDKOB |
Starting value torque filter when air-conditioner compressor is activated |
KFDMDPO |
Delta torque for starting negative slope limitation |
KFDMLSDO |
Delta torque for starting positive slope limitation |
KFDMLSDS |
delta torque for triggering of load-shock damping after shifting procedure |
KFDMP |
map for pedal influenced part of torque loss |
KFDMP_UC |
map for pedal dependant portion of torque loss in instruction test |
KFDMP_UM |
map for pedal dependant portion of torque loss |
KFDMT |
map for temperature dependent torque (level 1) |
KFDMT_UC |
map for temperature dependent torque in instruction level |
KFDMT_UM |
map for temperature dependent torque |
KFDTUMTAV |
map for offset intake-air temperature -> ambient temperature |
KFDWBHO1SK |
Delta angle for begin angle first suction stroke injection cold condition in inj |
KFDWNWDMXA |
Maximum deviation in camshaft position for error entry outlet |
KFDWNWDMXE |
Maximum deviation in camshaft position for error entry intake |
KFDYESPF |
Threshold for dynamic presetting values |
KFDYESPFOF |
Offset threshold for dynamic presetting values |
KFDZWHKS |
Delta ignition advance-angle map at GDI mode homogeneous knocking prevention |
KFDZWOHKS |
characteristic map for shift of optimal ignition angle in HKS mode |
KFDZWSPM |
delta latest ignition angle relative to engine temperature and air charge |
KFEIGMSV |
power dissipation influence to nmot and vfzg, MSV body temperature |
KFEONVPT |
Pressure threshold attainable only by system with leak less than 0.020"" |
KFFDLBTS |
Factor delta nominal Lambda for component protection |
KFFDMRKHLL |
factor for minimum required torque reserve during catalyst heating (in Idle) |
KFFDMRKHMN |
factor for minimum required torque reserve during catalyst heating |
KFFFANZ |
Number of sequential sparks |
KFFKASX |
characteristic map max. spec. purge fuel amount |
KFFMSDWKE |
Fuzzy correction factor for air flow adaptation step |
KFFNSAMX |
Map maximal value afterstart adaptation |
KFFNWSKRA |
factor for correction of desired cam angle due to knocking combustion |
KFFNWSKRE |
factor for correction of desired cam angle due to knocking |
KFFRARAW |
Amplification factor at AT |
KFFRARHG |
amplification factor |
KFFRKHK2K1 |
|
KFFRMIN |
lower limit of control range extended |
KFFTPKR |
Lowpass follow-up factor for stationary operation |
KFFUPSRLK |
fupsrl correction with high loads |
KFFUPSRLK |
fupsrl correction with high loads |
KFFWL |
map warm-up factor |
KFFWLKFTBR |
warm up correction for combustion chamber model |
KFFWLRL |
map warm-up factor load dependent fraction |
KFFWNWSIVL |
Correction Factor for NWS during Idle Speed Conditon |
KFFWNWSIVN |
Correction Factor for negative intake NWS |
KFFWNWSIVP |
Correction Factor for positive intake NWS |
KFGPRSOLFN |
Negative Gradient for Gradient Limiter- Rail pressure setpoint |
KFGPRSOLFP |
Positive Gradient for Gradient Limiter- Rail pressure Setpoint |
KFHSHUSOL |
Mapp. for heater voltage as a funct. of exhaust emis. temp. and msabg |
KFKASNH |
characteristic map max. spec. purge fuel amount limp home homogeneous |
KFKE0 |
Knock-detection factor characteristic map cylinder counter 0 |
KFKE1 |
Knock-detection factor characteristic map cylinder counter 1 |
KFKE2 |
Knock-detection factor characteristic map cylinder counter 2 |
KFKE3 |
Knock-detection factor characteristic map cylinder counter 3 |
KFKHFM |
HFM-correction characteristic map |
KFKHSWS |
map of required heat-flow of exhaust gas to heat catalyst after cranking |
KFKHSWSLL |
map of required heat-flow (during idle) of exh. gas to heat cat. after cranking |
KFKOMABNPU |
mrfa-threshold for not turning off A/C-compressor |
KFKRINT1G |
knock control: weighting integration value channel 1 |
KFKRINT2G |
knock control: weighting integration value channel 2 |
KFKRINT3G |
knock control: weighting integration value channel 3 |
KFKSTT |
factor cold start |
KFKSTTHDR |
factor cold start high pressure start |
KFKVB |
correction factor for fuel consumption signal |
KFLANS |
map lambda engine during afterstart |
KFLANSKH |
map lambda engine request at catalyst heating during afterstart |
KFLASWLR |
map lambda engine nominal at warming up with active A/F control |
KFLBTS |
Nominal Lambda for component protection |
KFLBTSBG |
Min setpoint value for component protection |
KFLDIMAX |
map boost control LDR i control limitation |
KFLDIOPU |
Correction of the duty cycle value by elevation |
KFLDIWL |
correction of LDR I-limitation at warm-up |
KFLDREGQ0 |
control parameter Q0 for boost control |
KFLDREGQ1 |
control parameter Q1 for boost control |
KFLDREGQ2 |
map control parameter Q2 for boost control |
KFLDRL |
Map for linearisation boost pressure =f(TV) |
KFLMSKH |
Performance characteristics lambda engine nominal at catalyst heating |
KFLRSG1 |
Characteristic map control parameter g1 continuous lambda controller |
KFLRSG2 |
Characteristic map control parameter g2 continuous lambda controller |
KFLRSG4 |
Characteristic map control parameter g4 continuous lambda controller |
KFLRSP1 |
Characteristic map control parameter p1 continuous lambda controller |
KFLRSP2 |
Characteristic map control parameter p2 continuous lambda controller |
KFLRSP3 |
Characteristic map control parameter p3 continuous lambda controller |
KFLRSP4 |
Characteristic map control parameter p4 continuous lambda controller |
KFLRST |
Map Time Delay |
KFLRSZ |
Characteristic map time constant of the LRS, 16-bit |
KFLSDWA |
Delta torque: release of load reversal damping at open lockup clutch |
KFLUAR |
map for engine roughness distance reference value |
KFLUAR1 |
map for engine roughness distance reference value |
KFLUAR2 |
map for engine roughness distance reference value |
KFLURB |
map for engine roughness - reference base value |
KFLURB1 |
map for engine roughness - reference base value |
KFLURB2 |
map for engine roughness - reference base value |
KFLURM |
reference base value map for engine roughness for misfire detection |
KFLURM1 |
reference base value map for engine roughness for misfire detection |
KFMAKR |
map for starting measuring window knock control |
KFMDBGRK |
Torque limitation for clutch protection |
KFMDELMX |
Torque intake generator |
KFMDKOB |
map for torque needed for air condition |
KFMDS |
map for engine drag torque |
KFMIFABG |
delta torque for gradient limitation |
KFMIFABGWK |
delta torque for gradient limitation at open clutch |
KFMIFALS |
Indicated driver's request torque for charge path at load-shock damping |
KFMILSD |
Initial value for positive torque slope limitation |
KFMIMN |
minimum drag torque |
KFMIOP |
map optimum engine torque |
KFMIOP |
map optimum engine torque |
KFMIOP |
map optimum engine torque |
KFMIOP |
map optimum engine torque |
KFMIRL |
map for calculation of nominal charge |
KFMIRL |
map for calculation of nominal charge |
KFMIRL |
map for calculation of nominal charge |
KFMI_UC |
map of optimum engine torque in instruction test |
KFMI_UM |
map of optimum engine torque in function monitoring |
KFMMKH |
Characteristic map higher permitted torque during Kat-heating |
KFMMKH_UC |
Characteristic map higher permitted torque during Kat-heating in instruction tes |
KFMMKH_UM |
Characteristic map higher permitted torque during Kat-heating |
KFMODI |
map for misfire modes and their parameter |
KFMOF |
map for offset tolerance depending on permissible torque (level 1) |
KFMOF_UC |
map for offset tolerance depending on permissible torque in instruction test |
KFMOF_UM |
map for offset tolerance depending on permissible torque |
KFMPZD_UC |
map rel. permissible torque pedal depending - Default Mode in instruction test |
KFMPZD_UM |
map for relative permissible torque pedal depending - Default Mode |
KFMPZP_UC |
map rel. perm. torque pedal depending - Performance Mode in instruction test |
KFMPZP_UM |
map for relative permissible torque pedal depending - Performance Mode |
KFMPZV_UC |
map rel. permissible torque pedal depending - Valet Mode in instruction test |
KFMPZV_UM |
map for relative permissible torque pedal depending - Valett Mode |
KFMRES |
LLR: torque reserve at idle and near-idle zone |
KFMRESFS |
LLR: torque reserve at idle and near-idle zone for B_fs=1 |
KFMRESK |
LLR: torque reserve at idle and near-idle zone clutch disengaged |
KFMRESKH |
Torque reserve during catalyst heating |
KFMRESNL |
Torque reserve in non idling state |
KFMRESTA |
Torque margin dependent on tans |
KFMSNWDKVP |
standardised air mass flow through throttle valve |
KFMSNWDKVP |
standardised air mass flow through throttle valve |
KFMSNWDKVP |
standardised air mass flow through throttle valve |
KFMSNWDKVP |
standardised air mass flow through throttle valve |
KFMSUDKN |
desired standardized over critical air mass flow rpm correction |
KFNLLNST |
idle speed after start |
KFNSKHLL |
map for control up engine during catalyst heating |
KFNSWLKPLANTF |
|
KFNSWRL |
weighting of afterstart enrichment |
KFNWEGM |
Fuel cut in map depending on rpm |
KFNWHOA |
Map f. camshaft spread ""high overlap"" (exhaust) |
KFNWHOE |
|
KFNWKHA |
Map f. camshaft spread at catalyst heating (exhaust) |
KFNWKHE |
Map f. camshaft spread at catalyst heating (intake) |
KFNWKHKA |
Map f. camshaft spread at catalyst heating cold engine (exhaust) |
KFNWKHKE |
Map f. camshaft spread at catalyst heating cold engine (intake) |
KFNWKHLLA |
Map f. camshaft spread at catalyst heating and B_II (exhaust) |
KFNWKHLLE |
Map f. camshaft spread at catalyst heating and B_II (intake) |
KFNWKHLLKA |
Map f. camshaft spread at catalyst heating and B_II cold engine (exhaust) |
KFNWKHLLKE |
Map f. camshaft spread at catalyst heating and B_II cold engine (intake) |
KFNWKRA |
desired cam angle for detonation outlet |
KFNWKRE |
desired cam angle for detonation inlet |
KFNWLLA |
Map f. camshaft spread during idling (exhaust) |
KFNWLLE |
map for camshaft position in idle (intake) |
KFNWRDA |
Characteristic map D portion of camshaft controller (outlet) |
KFNWRDE |
Map: D-portion of intake camshaft controller |
KFNWRPA |
Characteristic map D portion of camshaft controller (outlet) |
KFNWRPE |
Map: P-portion of intake camshaft controller |
KFNWRSIA |
I-map for cam-controller outlet |
KFNWRSIE |
I-map for cam-controller inlet |
KFNWSA |
Map f. camshaft spread (exhaust) |
KFNWSE |
map : nominal angle of camshaft, general conditions (intake) |
KFNWWLA |
Map f. camshaft spread during warm-up (exhaust) |
KFNWWLE |
map : nominal angle of camshaft at warm-up (intake) |
KFNWWLLA |
Map f. camshaft spread during warm-up at B_II (exhaust) |
KFNWWLLE |
Map f. camshaft spread during warm-up at B_II (intake) |
KFOSCHN |
Characteristic map OSC of a new main catalyst |
KFOSCKTD |
map of OSC of the end of life catalyst |
KFOSCUN |
OSC of a new non-monitored catalyst at the same operating point |
KFPEDR |
Pedal characteristic for reverse gear (only automatic transmission) |
KFPEDV |
accelerator pedal characteristic with vehicle speed |
KFPED_D |
Accelerator pedal characteristic, Map A (Default) |
KFPED_P |
Accelerator pedal characteristic, Map C (Performance) |
KFPED_V |
Accelerator pedal characteristic, Map B (Valet) |
KFPRGA |
int. partial exhaust gas press. dependent on cam.adjustment by outlet cam. contr |
KFPRGA |
int. partial exhaust gas press. dependent on cam.adjustment by outlet cam. contr |
KFPRGE |
int. partial exhaust gas press. dependent on cam.adjustment by inlet cam. contro |
KFPRGE |
int. partial exhaust gas press. dependent on cam.adjustment by inlet cam. contro |
KFPRNL |
Backup-value for rail-pressure sensor |
KFPRSOL |
Rail pressure setpoint |
KFPRSOL2 |
Map 2 of rail pressure setpoint |
KFPRSOL3 |
Map 3 of rail pressure setpoint |
KFPVTMSV |
Characteristic map pressure ratio over turbine |
KFPZU |
map for relative permissible torque from the pedal position in torque limitation |
KFPZUD |
map for rel. perm. torque from pedal pos. in torque limitation default-mode |
KFPZUP |
map for rel. perm. torque from pedal pos. in torque limitation performance-mode |
KFPZUV |
map for rel. permissible torque from pedal pos. in torque limitation valet-mode |
KFRA |
time constant for fra-integrator |
KFRAT |
Charge dependent gradient of FRAT integrator |
KFRBGOF |
|
KFRINH |
MAP for Nernst resistor post cat |
KFSDLUSDMR |
Map offset desired value standard deviation engine roughness |
KFSDLUSOL |
Map desired value standard deviation engine roughness |
KFSDLUSRRI |
Map desired value standard deviation engine roughness with inert gas |
KFTDDNWNPA |
Debouncing time for setting the error non-plausible position of outlet camshaft |
KFTDDNWNPE |
Debouncing time for setting the error non-plausible position of intake camshaft |
KFTEKAH |
characteristic map of desired fuel portion purge control in homogeneous mode |
KFTEVP |
Characteristic map for period time of the PCV |
KFTFUELAB |
map cool down curve |
KFTKRVFN |
time for ignition advancing knock ingnition |
KFTVLBTS |
Delay time nominal Lambda component protection f(nmot,rl) |
KFTVSA |
Retard time for overrun fuel cut-off |
KFUPSRLKNW |
fupsrl correction with high loads in case of shifted camshaft |
KFUPSRLKNW |
fupsrl correction with high loads in case of shifted camshaft |
KFURLA |
conversion factor from ps->rl dependent on cam.adjustment by outlet camshaft |
KFURLA |
conversion factor from ps->rl dependent on cam.adjustment by outlet camshaft |
KFURLE |
conversion factor from ps->rl dependent on cam.adjustment by inlet camshaft |
KFURLE |
conversion factor from ps->rl dependent on cam.adjustment by inlet camshaft |
KFUSHKW |
Map of set value in LRHK |
KFVADE |
factor decel. enleanment direct injection |
KFVERST |
weighting map for increasing control of friction torque |
KFVOFFS |
velocity offset for cruise control |
KFVPVSPLFS |
Map for desired pressure ratio: pressure upstream throttle over pressure downstr |
KFVSTMSVO |
offset feed forward control MSV |
KFWBHK2S1 |
Begin Angle of first suction stroke injn. in mode HK2 |
KFWBHO1SLE |
Begin angle of first suction stroke injn. in warm in mode HO1for charge motion>t |
KFWBHO1SWE |
Begin angle of first suction stroke injn. in warm in mode HO1, extended |
KFWBHP2S1 |
Begin Angle of first suction stroke injn. in mode HP2 |
KFWDKMSNVP |
desired throttle angle |
KFWDKMSNVP |
desired throttle angle |
KFWDKMSNVP |
desired throttle angle |
KFWDKPSPV |
filtering time of desired throttle angle |
KFWDKSMX |
max. desired throttle angle |
KFWEHK2K1 |
End angle of first compression stroke injection in mode HK2 |
KFWEHP2K1 |
End angle of the injection in compression stroke in mode HP2 |
KFWKSTAB |
factor cold re-start for reduction of starting fuel |
KFWKSTT |
map weighting of factor cold start |
KFWKSTTHDR |
map weighting of factor start with high fuel pressure |
KFWMABG |
map for heat-quantity threshold dew-point end upstream bank1 |
KFWMFK |
map for heat quantity threshold dew-point end downstream pre-catalyst |
KFWMKAT |
map for heat quantity threshold dew-point end downstream |
KFWNSNW |
map weighting afterstart-factor dependent on camshaft adjustment |
KFWNWANHS |
Nominal angle for camshaft (if not homogen or stratified mode) outlet |
KFWNWASCH |
Nominal angle for camshaft at Stratified-Mode outlet |
KFWNWENHS |
Nominal angle for camshaft (if not homogen or stratified mode) inlet |
KFWNWESCH |
Nominal angle for camshaft at Stratified-Mode inlet |
KFWNWSAPA |
Map f. camshaft spread during exhaust application phase |
KFWNWSAPE |
Map f. camshaft spread during intake application phase |
KFWNWWKA |
Weighting performance characteristica for NW nominal angle outlet |
KFWNWWKE |
Weighting performance characteristica for NW nominal angle inlet |
KFWPFGR |
Inverse pedal characteristic for cruise mode |
KFWSTAARL |
afterstart correction with start adaptation and relativ air charge |
KFWTBR |
Weighting factor Tans/Tmot for combustion chamber temperature model |
KFWWLML |
map weighting warm-up factor |
KFWWLNW |
map weighting warmup-factor dependent on camshaft adjustment |
KFWWNS |
repeated start time factor |
KFZDASH |
Time constant for negative torque slope limitation |
KFZDASH2 |
time constant PT1-filter dashpot at low clutch torque |
KFZLSD |
Time constant for positive torque slope limitation |
KFZW |
Ignition advance-angle characteristik map |
KFZW2 |
Ignition angle performance characteristics variant 2 |
KFZW2HSP |
|
KFZW2OUT |
Ignition angle performance characteristics variant 2 for outlet camshaft control |
KFZWA2HSP |
|
KFZWAHSP |
|
KFZWHSP |
|
KFZWMN |
Map for minimal ignition angle |
KFZWMNHSP |
Map for minimal ignition angle catalyst warm-up(HSP) |
KFZWMNKH |
Map for minimal ignition angle catalyst warm-up |
KFZWMNST |
minimal ignition spark advance for engine start and after start |
KFZWMS |
Map for ignition value as latest possible value |
KFZWOP |
optimum ignition angle |
KFZWOP2 |
Optimum ignition angle, variant 2 |
KFZWOP2D |
|
KFZWOPA |
optimal ignition angle for continuous exhaust valve camshaft-control position 0 |
KFZWOPA2 |
optimal ignition angle for continuous exhaust valve camshaft-control position 1 |
KFZWOPA2D |
|
KFZWOPAD |
|
KFZWOPD |
|
KFZWOUT |
Ignition advance-angle characteristik map of outlet camshaft control |
KFZWSTZT |
map ignition angle during start |
KFZWWLNM |
Delta ignition sparc advance during engine warm up phase |
KFZWWLRL |
Delta ignition sparc advance during engine warm up phase |
KFZW_UC |
map of optimum ignition angle in instruction test |
KFZW_UM |
map of optimum ignition angle |
KIFKFUPSRL |
Integrator coefficient for fupsrl adaptation |
KIFZGAWG |
amplification of vehicle model integrator at AT, converter clutch closed |
KIFZGHG |
amplification of vehicle model integrator |
KIHRLSU |
I boosting factor of PID controller for %HRLSU |
KILRHMLW |
I-component for continuous LRHK |
KIMSALL |
Correction value for idling air mass integrator for E gas |
KINMXNL |
Gain of integral component rpm control in case of disabled throttle drive |
KINMXRLG |
Gain of integral component rpm control for normal operation |
KIOFAPIRG |
Integrator coefficient for pirg adaptation |
KIVMXG |
Gain factor for I-component of VMAX control |
KKFFGRGA |
amplification rate during cruising for cruise control |
KLAF |
characteristic of Saint-Venant |
KLAF |
characteristic of Saint-Venant |
KLAF |
characteristic of Saint-Venant |
KLAFTE |
characteristic of Saint-Venant of purge control valve an line AKF-TEV |
KLALETM |
charakteristic for the turnback tooth periods |
KLAMST |
Integrator gradient for learning of factor flamkst_w |
KLAO2VK |
characteristic line to adapt O2 concentration (20.95%) bank 1 |
KLATMABKHK |
Factor for temperature decrease main catalyst = f(off-time) |
KLATMABKVK |
Factor for temperature decrease pre-catalyst = f(off-time) |
KLDETAZWKH |
Minimum distance to minimal spark efficiency while spark retard for cat. heat. |
KLDFOFF |
Threshold to switch off generator load |
KLDFON |
Threshold to switch on generator load |
KLDFPWMDEF |
|
KLDIFSEG |
Fixed value characteristic for weighting the angular displacement |
KLDKVZB |
Characteristic line for delay time of time constant ZKMDKOV |
KLDLSHKFO |
characteristic curve to variate the set value by aged catalyst |
KLDLUL |
Threshold negative deviation of boost pressure for detecting overcharge pressure |
KLDMASRL |
setting reserve at ASR intervention |
KLDMDWMX |
limitation of converter torque for safety concept |
KLDMMX |
Maximum delta torque for air path |
KLDMWDK |
speed dependensy of throttle-angle for Wide Open Throttle |
KLDMXRLU |
variation limitation for max. reduction of the engine roughness reference values |
KLDNFHO |
Weighting minimum difference in engine-speed for detected combustion |
KLDNLLDE |
characteristic curve: torque reserve for speed undershoot |
KLDTMFXTM |
charact. line delta TMOT- threshold for not plausible fixed signal |
KLDTPH |
Fixed value characteristic for weighting the engine dynamic |
KLDTPHST |
Fixed value characteristic for the engine start |
KLDYNCOR |
Value for the dynamic correction after the first ignition |
KLDZWLA_UC |
Lambda dependency of optimum ignition angle in instruction test |
KLDZWLA_UM |
Lambda dependency of optimum ignition angle in function monitoring |
KLDZWOM_UC |
temperature-dependent offset of opt. ignition angle in instruction test |
KLDZWOM_UM |
temperature-dependent offset of opt. ignition angle in monitoring |
KLETALA_UC |
Lambda efficiency in instruction level |
KLETALA_UM |
Lambda efficiency in function monitoring |
KLETALS_UC |
Lambda efficiency with stratified charge in instruction test |
KLETALS_UM |
Lambda efficiency with stratified charge in function monitoring |
KLETAVGMN |
Lookup table minimum defined efficiency |
KLETAZW_UC |
ignition efficiency depending on delta ignition angle in instruction test |
KLETAZW_UM |
ignition efficiency depending on delta ignition angle in monitoring |
KLFACRML |
Correction factor rml |
KLFAKSP |
characteristic line for efficiency of split |
KLFAKSP_UC |
characteristic line for efficiency of split in instruction test |
KLFAKSP_UM |
characteristic line for efficiency of split in function monitoring |
KLFANFKH |
Weighting factor for requrirements (wsanfkh_w, tanfkh_w) for catalyst heating |
KLFDTFUEL |
curve factor temperature dependent fuel density |
KLFEXPSL |
Characteristic line E-function (1-e(-x)) |
KLFKAMAAVK |
weighting factor f(avkatf) for OSC ratio of monitored/non monitored cat |
KLFKAMAIML |
weighting factor f(imlka_w) depending on duration of fuel cut off |
KLFKAMAOSC |
weighting factor f(fcoschk) for OSC ratio of monitored/non monitored cat |
KLFKVNWANM |
Correction factor of calculate control velocity from camshaft control outlet |
KLFKVNWENM |
correction factor of calculate control velocity from camshaft control inlet |
KLFLAKH |
Weighting factor for control factor flakh for Lambda while catalyst heating |
KLFMDWAN |
Factor to correct the converter torque depending of stationary idle speed |
KLFMRMNWI |
weighting factor for controled increase of minimal necessary torque reserve in d |
KLFNSWLKPR |
Interface rail-pressure correction factor for afterstart and warm-up |
KLFRKHP2K1 |
Injection quantity split factor in HSP double injection |
KLFSTTEWM |
fuel level replacement values depends from integrated CPV-mass flow at vacuum bu |
KLFTEAD |
curve factor purge control adaptation |
KLFTOL |
correction factor stop time dependent |
KLFTWDKSR |
Weighting factor thdk_w/tmotk for combustion chamber temperature model |
KLFVSTGTF |
gain correction of feed forward control MSV dependant on fuel temperature |
KLFVSTOTF |
offset correction of feed forward control MSV dependant on fuel temperature |
KLFWFRL |
curve factor max. injection angle range for calculation max. load |
KLFWLKAPR |
|
KLFWLN |
characteristic line weighting warm-up factor |
KLFWSANFHO |
Factor for controlled increase and decrease of heating flow in dependence of alt |
KLFZWMNKH |
Spark retard gradient of burning limit during after-start at cat.heating |
KLFZWMNST |
Spark retard gradient of burning limit during after-start |
KLHDEV |
HPIV master charcteristic curve |
KLHDHSPANZ |
max. number of combustions in hsp mode at high pressure start |
KLIMHKGIB |
Mass flow threshold in i-part after bank independent balance errors |
KLIMHKIB |
Mass flow threshold in i-part after bank dependent balance errors |
KLIMHKPB |
Mass flow threshold in p-part after bank dependent balance errors |
KLIMLNA |
Gradient constant for non-active debouncing |
KLIMSTEFV |
Curve decrease factor fuel part error suspicion fuel purge control |
KLKFWSHML |
Correction factor for heat transition to engine coolant at GDI's specific modes |
KLKIWMA |
Corrective characteristic for integrated heat quantity upstream sensor |
KLKIWMFK |
Corrective characteristic for integrated heat quantity middle sensor |
KLKIWMK |
Corrective characteristic for integrated heat quantity downstream sensor |
KLKTKVK |
characteristic line: proportional factor between temp. deviation and corr.factor |
KLLAKHFH |
ambient pressure correction lambda catalyst heating |
KLLAMFAHO |
Lambda driver demand, high overlap |
KLLDTVGS |
duration of negative offset on boost control duty cycle |
KLLLRZU |
table for permissible torque of idle control |
KLLLRZU_UC |
characteristic of permitted torque for idle speed control in instruction test |
KLLLRZU_UM |
characteristic of permitted torque for idle speed control |
KLLUTS |
Amplification factor engine roughness |
KLMDLFTV |
look-up-table electric fan-torque |
KLMIMAX |
table for maximum indicated engine torque |
KLMIMAX_UC |
characteristic of maximum torque in instruction test |
KLMIMAX_UM |
characteristic of maximum torque |
KLMIMIN |
table for minimum indicated engine torque |
KLMIMIN_UC |
characteristic of minimal torque in instruction test |
KLMIMIN_UM |
characteristic of minimal torque |
KLMIMNH |
altitude correction of mimin_w |
KLMISALULC |
altitude correction for misalull |
KLMKTFUEL |
Temperature impact mk on fuel temperature |
KLMRESLI |
map: temperature depending torque reserve limit |
KLMRESTM |
characteristic for torque reserve after start |
KLMRHO |
map: altitude depending torque reserve |
KLMRKFHO |
Correctionb factor altitude depending torque reserve |
KLMSSTLD |
characteristic linie requested CPV-Mass-Flow over time for tank leakage diagnosi |
KLMSUDKKH |
desired standardized over critical start air mass flow at catalyst heating |
KLMSUDKPED |
desired standardized over critical air mass flow offset pedal value |
KLMSUDKTM |
desired standardized over critical air mass flow at start |
KLMZUMN |
map for engine speed dependent torque |
KLMZUMN_UC |
charcteristic for engine speed dependent torque in instruction test |
KLMZUMN_UM |
characteristic for engine speed dependent torque |
KLNDNWAMN |
Characteristic line minimum engine speed for diagnosis outlet camshaft control |
KLNDNWEMN |
Characteristic line minimum engine speed for diagnosis inlet camshaft control |
KLNLLV |
desired speed depending on vehicle speed. |
KLNMSVZPAS |
threshold engine speed MSV two-point-control dependant on engine temperature |
KLNPED_UC |
Speed lim. as func. of nom. pedal value, in DK drive standby; instruction test |
KLNPED_UM |
Speed lim. as func. of nominal pedal value, in DK drive standby func.,func.mon. |
KLNSADI |
Characteristic line integrator part of afterstart adaptation |
KLNSADP |
Characteristic line proportional part afterstart adaptation |
KLPBR |
Fixed characteristic for pressure in the combustion compartment |
KLPRAIL |
Characteristic for switchover of rail-pressure sensor voltage into rail pressure |
KLPRFTDGN |
Curve for primary fuel tank diagnosis |
KLPRFTDSP |
Curve for Primary Fuel Tank Display |
KLPRGAGPS |
CL for corr. of pbrintro_w dependent on pressure rate manifold/exhaust valve |
KLPRGAGPS |
CL for corr. of pbrintro_w dependent on pressure rate manifold/exhaust valve |
KLPRHLSU |
Characteristic line of relative heater output to initialize accumulator |
KLPRMAXTF |
characteristic line setpoint pressure limitation dep. on fuel temperature |
KLPRMXNMX |
max.setpoint-value rail pressure at engine speed limiter |
KLPRMXPRC |
limit for range check, dependent on nmot |
KLPROSTHD |
Threshold rail pressure for start with high fuel pressure |
KLRAMP |
Cylinderdeactivation pattern for EMOP |
KLREDNMX |
maximum reduction step for sequential fuel cutoff (depending on gear), engine sp |
KLRKMSVZPA |
threshold relative fuel mass MSV two-point-control dependant on engine temperatu |
KLRSTHDR |
Number of synchros for waiting for high fuel pressure |
KLRTLSU |
Caracteristic line: transfomation of internal resistor of nernst cell into temp. |
KLSDTHMS |
charc.-line for rising constant of thermostat temp.model depend. on start temp. |
KLSECFTDGN |
Curve for secondary fuel tank diagnosis |
KLSECFTDSP |
Curve for Secondary Fuel tank Display |
KLSEISAT |
Kennlinie f(tmot) |
KLSWKH |
Characteristic: requested quantity of heat for catalyst-heating after cranking |
KLTAMSVUBS |
Control MSV - duty cycle (UserTrigger-Mode) |
KLTANZTI |
Maximum number of allowed injections |
KLTATRS |
Set temperature for exhaust gas temperature control |
KLTCWCSTAB |
characteristic curve for exponentially tmot-cooling down |
KLTFA1MX |
high-side-check TFA1: maximum temperature threshold |
KLTFLPR |
influence of tans and tmot to tfuelhpm |
KLTFLTANS |
influence of tans to fuel temperature |
KLTGETV |
phase of negative offset on boost control duty cycle |
KLTHKIMN |
Lower temperture threshold to enable i-part |
KLTHKPMN |
Lower temperture threshold to enabel p-part |
KLTIKRPR |
ti-correction for variable rail pressure |
KLTIPR_UM |
proportionality of rel. fuel mass an injection pressure |
KLTMOTDIFF |
Difference of engine temperature during ecu-afterrun for condition hot start |
KLTMTAMSV |
curve for basis MSV temperature |
KLTNMXPR |
Time for engine speed prediction of rpm control |
KLTNRDE |
characterisitic for tooth times at reverse rotation |
KLTNWADSTE |
Characteristic delay time after end of start to enable diagnosis outlet camshaft |
KLTNWEDSTE |
Characteristic delay time after end of start to enable diagnosis inlet camshaft |
KLTOLTUM |
Correction factor for oil temperature for variable tumg |
KLTOSF |
Characteristic curve engine oil temperature dependent penalty factor |
KLTPLHKAB |
characteristic curve of time constant to correct H2 |
KLTROCLAA |
Threshold for Time counter concerning application of adaption ramp step |
KLTUMTAB |
Correction of ambient temperature modell at coldstart |
KLTUMTFUEL |
influence of ambient temperature to fuel mass |
KLTVDIFF |
value of negative offset on boost control duty cycle |
KLTVDMFBR |
debounce time after disengage the gear |
KLTVRSTHDR |
Max. waiting time for high fuel pressure |
KLTVTS_UM |
open time delay depended on fuel pressure |
KLTWSKWTMS |
release heat.flow requirement for catalyst heating after end of start |
KLVMAXMTPROC |
|
KLVSTDP |
Characteristic dynamic portion from prsoll_w gradient pre-control MSV |
KLVZMSVT |
temperature dependant correction of pull-in impulse MSV control |
KLVZMSVUB |
MSV delay time dependent on battery voltage |
KLWBHO1SMX |
Max. Begin Angle of the first compression stroke injn. in mode HO1 |
KLWESABR |
Characteristic line of injection abortion angle |
KLWESHXK1 |
Char. Line of end angle of compression stroke injection in SHX mode |
KLWFLHXXS |
Interpolation factor lambda-KF begin angle in HO1 |
KLWFWHXXS |
Interpolation factor between warm/cold KF begin angle in mode HO1/2, HP2/3 |
KLWMKKHFSO |
Corrective characteristic for heat quantity while catalyst heating middle sensor |
KLWMKKHHSO |
Corrective characteristic for heat quantity while catalyst heating downstream se |
KLWMKKHVSO |
Corrective characteristic for heat quantity while catalyst heating upstream sens |
KLWMSABST |
correction desired standardised over critical air mass flow by soak time |
KLWNWPAS |
Fixed value characteristic for weighting the angular displacement |
KLWNWSLRA |
Characteristic line for setpoint-outlet-camphaser error simulation |
KLWNWSLRE |
Characteristic line for setpoint-inlet-camphaser error simulation |
KLWSATAVS |
weighting heat. flow requirement in dep. from temperature of front oxyg.-sensor |
KLZANSFHO |
characteristic line for weighting of high for afterstart deactivation |
KLZDLBTS |
|
KLZKMDWA |
Time constant for increasing the torque demand of the converter |
KLZKMDWAA |
Time constant for decreasing the torque demand of the converter |
KLZKNSADI |
Characteristic line integrator time constant afterstart adaptation |
KLZNFILT |
time constant for engine gradient filter |
KLZNSM |
time constant for decay of desired idling speed |
KMFMSNDKER |
Low pass filter multiplier for relative error calculation |
KMFST12SK |
|
KMFST1SK |
|
KMFST2SK |
|
KMFSTDEN |
|
KMSDK |
gain factor for filtering msdk |
KNLSYN |
Security factor for synchronisation condition |
KNSNF |
Engine speed follow-up inhibition band |
KO2INI |
Inital value for correction of functional pumping current LSU |
KO2MN |
Min. allowable correction factor for correction of functional pumping current |
KO2MX |
Max. allowable correction factor for correction of functional pumping current |
KO2VKDMN |
Lower diagnosis threshold for adaptation factor ko2vk |
KO2VKDMX |
Upper diagnosis threshold for adaptation factor ko2vk |
KO2VKEMN |
min. threshold for settled criterion |
KO2VKMN |
Minimum adaptation factor ko2vk |
KO2VKMX |
Maximum adaptation factor ko2vk |
KOELTH |
Thermal Time Constant for Engine Oil |
KOFPSXS |
time constant of integrator for calculation of ofpsxs_w (ps-controller) |
KORA |
integration speed integrator ORA |
KORIPHCSA |
IP-correction in fuel cut off (HC) |
KPATRDT |
proportional gain for exhaust temperature control over temperature deviation |
KPHRLSU |
P boosting factor of PID controller for %HRLSU |
KPLRHML |
P-component for continuous LRHK |
KPVLLKF |
Amplification factor of high pass for pvllk_w filtering |
KPVLLKHP |
Amplification factor of high pass for pvllk_w filtering |
KPVMXG |
Gain factor P-component of VMAX control |
KPWGL |
Filter constant for calculation of new pedal idle value |
KRAFGRGA |
amplification rate at ramp for cruise control |
KRAL1N |
load range for adaption maps 1 |
KRAL2N |
load range dor adaption maps 2 |
KRAL3N |
load range for adaption maps 3 |
KRAL4N |
load range for adaption maps 4 |
KRAL5N |
load range for adaption maps 5 |
KRALH |
load hysterisis for adaptation maps |
KRAN1 |
speed range for adaption maps, Stützstelle 1 |
KRAN2 |
speed range for adaption maps, Stützstelle 2 |
KRAN3 |
speed range for adaption maps, Stützstelle 3 |
KRAN4 |
speed range for adaption maps, Stützstelle 4 |
KRANH |
n hysterisis for adaptation maps |
KRANH |
n hysterisis for adaptation maps |
KRDWA |
knock control difference current ignition angle to adaption map |
KRDWKLA |
The SV-learning value for KR adaption after knocking detected |
KRDWSA |
The FV-learning value for KR adation when wkra-wkr > KRDWA |
KRDYESP |
threshold for load dynamics detection with accelerator pedal |
KRDYESPOF |
Offset f. load dynamics with acctuator pedal value |
KREDYLSH |
Filter constant EWMA dynamik measurement sensor downstream cat. |
KRFHKS |
fault frequency - knock sensors |
KRFHT |
error frequency, test pulse |
KRFTP2 |
low pass characteristic at engine speed dynamics |
KRFTP3 |
low pass characteristic at load dynamic |
KRIVKMX |
maximum correction value krivk_w |
KRKATE |
conversion from relative fuel mass rk into effective injection time te |
KRKFKS |
selected knock detection threshold, if missing cylinder one detection |
KRLNMDY |
Read if change of load / speed range: always or only if dynamics conditions |
KRRKRGKL |
kc: weighting for limitation reference value calculation at knocking |
KRRKRGN |
kc: weighting for limitation refernce value calculation without knocking |
KRUMOB |
upper threshold for the amplification control |
KRUMUNT |
lower threshold for the amplification control |
KRVST |
gain after cranking |
KRZYLDIAG |
Selection of (noisy) cylinders for KS-diagnosis |
KSTA0INI |
Initialization value of STADAP factor in range 0 |
KSTA1INI |
Initialization value of STADAP factor in range 1 |
KSTA2INI |
Initialization value of STADAP factor in range 2 |
KSTAI |
workingrange for STADAP factor |
KSTAMN0 |
Minimum limit of STADAP factor in range 0 |
KSTAMN1 |
Minimum limit of STADAP factor in range 1 |
KSTAMN2 |
Minimum limit of STADAP factor in range 2 |
KSTAMX0 |
Maximum limit of STADAP factor in range 0 |
KSTAMX1 |
Maximum limit of STADAP factor in range 1 |
KSTAMX2 |
Maximum limit of STADAP factor in range 2 |
KSTANSAD |
Threshold factor start adaptation for activation of afterstart adaptation |
KSTEIG |
Recursion constant for LSU gradient |
KSTTOPMN |
minimum operating time since PWF for starting fuel adaptation |
KTEVANMK |
characteristic line for purge valve opening speed |
KTLAMSTEIG |
I-factor for ramp lamlash in short test for test function post catalyst |
KTMLUSTEST |
air mass threshold for start of test oscillation check for short trip |
KTMOTW |
Engine temperature at warm engine |
KTMOTW |
Engine temperature at warm engine |
KTNWSABGKA |
Time constant f. des.val.change limit. exhaust cam. cold |
KTNWSABGKE |
Time constant f. limit. of des. value change (intake camshaft / cold) |
KTNWSNABGA |
Time constant f. neg. des.val.change limit exhaust cam. |
KTNWSNABGE |
Time constant f. negative limit. of des. value change (intake camshaft) |
KTNWSPABGA |
Time constant f. pos. des.val.change limit. exhaust cam. |
KTNWSPABGE |
Time constant f. positive limit. of des. value change (intake camshaft) |
KTRDYLSH |
Filter constant EWMA dynamik measurement sensor downstream cat. |
KUMSIRL |
conversion constant from mass flow to relative air charge |
KUMSIRL |
conversion constant from mass flow to relative air charge |
KUSVKMX |
max. correction value of offset of output amplifier of evaluation IC of LSU |
KVLAD |
air charge correction caust by boost pressure dynamic |
KWABSMNP |
minimum acceleration for plausibility check of brake switch |
KWDKV2P41 |
Number of fault pathes for definition of the PID$41-group of %DKVS |
KWDMD2P41 |
|
KWHLS2P41 |
|
KWHLS2P41 |
|
KWKAT2P41 |
|
KWKAT2P41 |
|
KWKOZBS |
Threshold for short distance drives until service |
KWKWUP |
Threshold for effective revolution limit |
KWLS2P41 |
|
KWLS2P41 |
|
KWMZKBS |
Threshold for minimum distance until oil service |
KWOLEEZ |
Debounce timer for engine coolant sensor error |
KWOLUET |
Temperature threshold for engine oil overheating |
KWPBOW |
Percentage oil change soon |
KWPSOW |
Percentage oil change now |
KWTAHFM |
Replacement value for the value of the second intake air temperature sensor TAHF |
KWTES2P41 |
|
KWTES2P41 |
|
KWTMSKOZ |
Threshold for engine coolant temperature for short distance drive |
KWVBP |
deceleration threshold for plausibility check of brake signals |
KWVBPMN |
|
KWVBSMNP |
minimum deceleration for plausibility check of brake switch |
KWZKBS |
Threshold for recommended distance until service |
KWZUBS |
Threshold for revolution packages until service |
KW_TDCAS |
|
KW_TDCGE |
|
KW_TDDTCS |
|
KW_TDNECAS |
|
KW_TDNECGE |
|
KZUECONFV |
number of configurations at error |
LADFIL |
boost pressure filtering for calculation of delta boost pressure |
LADIFFTHR |
Threshold for lambda difference for LRS-reset at enleanment protection |
LADMNHOM |
minimum permissible lambda for homogeneous mode |
LADMXHOM |
maximum permissible lambda for homogeneous mode |
LAKAMSAIML |
lambda setpoint for cat deox. (dependent exhast gas mass and rich-integral) |
LAKTDE |
Lambda threshold for lambda stabilized, cat monitoring |
LAKTDF |
lambda value (rich), cat. monitoring |
LAKTDFT |
lambda value (rich), cat. monitoring, final test |
LAKTDM |
lambda value (lean), cat. monitoring |
LAKTDMT |
lambda value (lean), cat. monitoring, final test |
LALIO |
Characteristic line lambda=f(oxygen concentration) |
LALIUSHK |
lambda linearization, sensor behind catalyst, quantification 0 ...<2 |
LALIUSMN |
minimum measurable lambda |
LALIUSMN |
minimum measurable lambda |
LALIUSMN |
minimum measurable lambda |
LAMDYNO |
Upper lambda threshold for dynamics check LSU |
LAMDYNU |
Lower lambda threshold for dynamics check LSU |
LAMFA |
Lambda driver demand |
LAMFRATX |
delta lambda for the enabling of FRAT-intergrators |
LAMGAINMN |
Lambda lower limit for gain = 17 in CJ125 |
LAMGAINMX |
Lambda upper limit for gain = 17 in CJ125 |
LAMGAMN |
minimum of lambda threshold for mixture adaptation active |
LAMHAP |
desired lambda for application homogeneous mode |
LAMKADEF |
default lambda value for catalyst purge function is inactive |
LAMLASHMIN |
Min. Lambda set point (rich) for the test oscillation check downstream cat |
LAMMNST |
minimum lambda threshold for sensor signal trimming |
LAMNHOM_UC |
Lower Bound for Lambda in Instruction Test |
LAMNHOM_UM |
Lower Bound for Lambda in Function Monitoring |
LAMNMAG_UC |
Minimum Lambda for Lean Modes in Instruction Test |
LAMNMAG_UM |
Minimum Lambda for Lean Modes in Function Monitoring |
LAMNSCH_UC |
Minimum Lambda for Stratified Mode in Instruction Test |
LAMNSCH_UM |
Minimum Lambda for Stratified Mode in Function Monitoring |
LAMSBRSLN |
Lambda threshold for condition O2 purging of catalyst |
LAMSKAMX |
upstream lambda for detection of lean condition of cat oxygen neutralization |
LAMSSMN |
Minimum set value for lambda in stoichiometric operation |
LAMSSMX |
Maximum set value for lambda in stoichiometric mode |
LAMSTEIG |
I-factor for ramp increase lamlash for tst function post catalyst |
LAMTEMN |
minimum of lambda threshold for canister purge control active |
LAMXHOMKH |
Maximum lambda request for catalyst heating while homogenous operatione |
LAMXHOM_UC |
Upper Bound for Lambda in Instruction Test |
LAMXHOM_UM |
Upper Bound for Lambda in Function Monitoring |
LAMXMAG_UC |
Maximum Lambda for Lean Modes in Instruction Test |
LAMXMAG_UM |
Maximum Lambda for Lean Modes in Function Monitoring |
LAMXSCH_UC |
Maximum Lambda for Stratified Mode in Instruction Test |
LAMXSCH_UM |
Maximum Lambda for Stratified Mode in Function Monitoring |
LAMZKMN |
minimum lambda threshold for sensor signal trimming |
LASOAB |
target lambda value for bank shutdown |
LASTCMN |
Lower bound for stoichiometric lambda |
LASTCMX |
Upper bound for stoichiometric lambda |
LASTEIGDIA |
threshold for diagnosis LSU-signal gradient |
LASTEIGMN |
threshold for diagnosis LSU-signal gradient too low |
LBMINC |
Value accumulated if there is a loss of the reference gap |
LBMINIT |
Initializing value for the counter of lost reference marks |
LBMMX |
Maximum value of the counter for lost reference gaps |
LBMSUB |
Differential value between the registration of E_bm and the activation of NLDG |
LBTSSAMX |
Upper end-lambda for component protection before fuel cutoff is released |
LBTSSTART |
Enrichment, from which lambda-request for component protection is put to lambda |
LDAMN |
Min-limitation of the LDR adaption (I-part) |
LDDIAN |
Delta per calculation for negative updating i controler limit |
LDDIAP |
Delta per calculation for positive updating i controler boost control |
LDEPVDIAO |
Upper boost control deviation threshold for negative correction |
LDEPVDIAP |
Controler deviation for adaption positive i part limitation |
LDEPVDIAPS |
Threshold controller deviation for fast positive update |
LDEPVDIAU |
Lower boost control deviation threshold for negative correction |
LDHIA |
Hysteresis for boost control i adaption characteristic line |
LDIMXAKMAX |
maximum limitation of ldimxak_w |
LDMXCAN |
Maximum boost pressure sent on CAN |
LDMXNN |
Limitation max. correction boost control negative by controler adaption |
LDMXNP |
Limitation max. correction boost control adaptation positive at area change |
LDRAPP |
Fixed value for boost control application without torque coordination |
LDRPBU |
P controller characteristic value back up boost control |
LDRQ0S |
Controller parameter Q0 boost control PID-controller at statisstate condition |
LDRQ1ST |
Controller parameter Q1 PID-controller at statistate condition |
LDRVL |
Full load detection threshold boost control |
LDTVGW |
Quantity of the negative duty cycle from the boost pressure control intervention |
LFAN0OF |
fan power threshold---> speed 0 off |
LFAN1OF |
fan power threshold---> speed 1 off |
LFAN1ON |
fan power threshold---> speed 1 on |
LFAN2OF |
fan power threshold---> speed 2 off |
LFAN2ON |
fan power threshold---> speed 2 on |
LFAN3OF |
fan power threshold---> speed 3 off |
LFAN3ON |
fan power threshold---> speed 3 on |
LFAN4OF |
fan power threshold---> speed 4 off |
LFAN4ON |
fan power threshold---> speed 4 on |
LFAN5OF |
fan power threshold---> speed 5 off |
LFAN5ON |
fan power threshold---> speed 5 on |
LFAN6OF |
fan power threshold---> speed 6 off |
LFAN6ON |
fan power threshold---> speed 6 on |
LFAN7ON |
fan power threshold---> speed 7 on |
LFANCOME |
Substitute value: Fan Command |
LFANSLMN |
minimum percentage of fan power when slip power management required |
LFANSLMX |
maximum percentage of fan power when slip power management required |
LFANWPED |
fan power when a wide open throttle condition exists |
LFCO1MN |
fan power threshold (resonance) Band 1 mini |
LFCO1MX |
fan power threshold (resonance) Band 1 maxi |
LFCO2MN |
fan power threshold (resonance) Band 2 mini |
LFCO2MX |
fan power threshold (resonance) Band 2 maxi |
LFCO3MN |
fan power threshold (resonance) Band 3 mini |
LFCO3MX |
fan power threshold (resonance) Band 3 maxi |
LFCO4MN |
fan power threshold (resonance) Band 4 mini |
LFCO4MX |
fan power threshold (resonance) Band 4 maxi |
LFND1 |
State of output driver 1 which corresponds with fan speed 0--6 |
LFND2 |
State of output driver 2 which corresponds with fan speed 0--6 |
LFND3 |
State of output driver 3 which corresponds with fan speed 0--6 |
LFREQAC |
percentage of fan power when A/C request and no A/C Pressure sensor present |
LFREQAF |
desired fan power for after-run fan operation |
LFREQAFHI |
Fan-speed during high speed atfer-run |
LFREQFZMN |
Vehicle %fan required threshold below which the adjustment of fan speed is used |
LFREQFZMX |
Vehicle %fan required threshold above which no adjustment of fan speed is allowe |
LFREQMAX |
maximum fan power for fan on |
LFREQMAX |
maximum fan power for fan on |
LFREQMN |
minimum fan power for fan on |
LFREQMN |
minimum fan power for fan on |
LFREQPAC |
percentage of fan power required for the AC high side pressure sensor |
LFREQPAC0 |
Fan control depending on pressure air condition, step 0 |
LFREQPAC1 |
Fan control depending on pressure air condition, step 1 |
LFREQPAC2 |
Fan control depending on pressure air condition, step 2 |
LFREQPAC3 |
Fan control depending on pressure air condition, step 3 |
LFREQPACC |
Fan control depending on pressure air condition, cold ambient |
LFREQTA |
Percentage of fan power required for tans-depending fan request |
LFREQTM0 |
Fan control depending on engine temperature, step 0 |
LFREQTM1 |
Fan control depending on engine temperature, step 1 |
LFREQTM2 |
Fan control depending on engine temperature, step 2 |
LFREQTM3 |
Fan control depending on engine temperature, step 3 |
LFREQTMC |
Fan control depending on engine temperature, cold ambient |
LFREQTMOT |
percentage of fan power required for the engine temperature |
LFREQTOMX |
Fan power threshold below which device control is allowed |
LFSDCSMIN |
Cooling fan speed min threshold for a device control |
LHAAAA |
Dummy fid: Limit High (Mode A) |
LHAAAA |
Dummy fid: Limit High (Mode A) |
LHAFRA |
High limit: Mode A, range FRA of LRA |
LHAFRAT |
|
LHAORA |
High limit: Mode A, range ORA of LRA |
LHATEH |
High limit: Mode A, purge control at high load |
LHATEL |
High limit: Mode A, purge control at low load |
LHATEN |
upper priority limit (insufficient active) emergency canister purge |
LHATLDI |
|
LHATLDO |
|
LHBAAA |
Dummy fid: Limit High (Mode B) |
LHBDLSU |
|
LHBFRST |
High limit: Mode B, short test of close loop control |
LHBHKT |
Upper priority limit (insufficiently active) DKATSP |
LHBHKT2 |
Upper priority limit (insufficiently active) DKATSP |
LHBLASH |
High limit: Mode B, function DLSAHK |
LHBLLRH |
upper priority limit (insufficient active) idlespeed deviation HOM |
LHBLLRKH |
upper priority limit (insufficient active) idle speed control diagnosis |
LHBPLSU |
|
LHCAAA |
|
LIMAIRTFA1 |
air-mass threshold used for limitation of intake air temperature sensor tfa1 af |
LIMAIRTFA2 |
air-mass threshold used for limitation of intake air temperature sensor tfa2 af |
LIMN |
lower integrator limit for standing car |
LIMNDLLR |
lower integrator limit for diagnostic of idle speed control |
LIMNDTES |
lower integrator limit for DTES |
LIMNV |
lower integrator limit for rolling car |
LIMXDNS |
upper integrator limit for standing car |
LIMXVDNS |
upper integrator limit for rolling car |
LISTM |
value of idle speed control integrator during start |
LIVFZDE |
Speed limit for speed undershoot. |
LKRN |
load-signal threshold knock control |
LLRICNF |
Configuration byte for ISC integrator |
LLSUSCHUB |
Lambda-Threshold for sensor LSU upstream catalyst after fuel cut-off (dynamic) |
LLSUSCHUBH |
Lambda-Threshold for sensor LSU upstream catalyst after fuel cut-off for measur |
LMSTMOT |
tmot-correction of lambda engine nominal |
LOAAAA |
Dummy fid: Limit LOw (Mode A) |
LOAAAA |
Dummy fid: Limit LOw (Mode A) |
LOAFRA |
Low limit: Mode A, range FRA of LRA |
LOAFRAT |
|
LOAORA |
Low limit: Mode A, range ORA of LRA |
LOATEH |
Low limit: Mode A, purge control at high load |
LOATEL |
Low limit: Mode A, purge control at low load |
LOATEN |
lower priority limit (sufficient active time) emergency canister purge |
LOATLDI |
|
LOATLDO |
|
LOBAAA |
Dummy fid: Limit LOw (Mode B) |
LOBDLSU |
|
LOBFRST |
Low limit: Mode B, short test of close loop control |
LOBHKT |
Lower priority limit (sufficiently active) DKATSP |
LOBHKT2 |
Lower priority limit (sufficiently active) DKATSP |
LOBLASH |
Low limit: Mode B, function DLSAHK |
LOBLLRH |
lower priority limit (sufficient active time) idlespeed deviation HOM |
LOBLLRKH |
lower priority limit (sufficient active time) idle speed control diagnosis |
LOBPLSU |
|
LOCAAA |
|
LRFHIMN |
minimum limit for dlatrmo |
LRFHIMX |
maximum limit for dlatrmo |
LRHIMN |
minimum integrator limit of the continuous LRHK |
LRHIMX |
maximum integrator limit of the continuous LRHK |
LRHKCMN |
Threshold of control value |
LRHKCMX |
Threshold of control value |
LRNST1NL_T |
Time until throttle valve should open after lower mechanical stop-learning in ru |
LRNST1_T |
Waiting time during learning step 1 |
LRNST2NL_T |
Time after which the throttle valve has to be opened after lower mechanical stop |
LRNST3_T |
Waiting time during learning step 3 |
LRNVBNL_T |
Time until the throttle valve adaption is started after motor shut down |
LRNVB_T |
Time during which learning is forbidden for 'normal learning' |
LRSGKTM |
Correcting char. line of the control parameters at low engine temperatures |
LRSMODMS |
Characteristic line amplitude of a/f ratio modulation in LRS |
LRSTPZA |
Periode time of the LRS compulsory amplitude |
LTERMFSFT |
Generator L-Terminal default value for rvcltdc |
LUARMI |
Engine roughness distance reference value, vehicle speed zero |
LURBMI |
reference value for engine roughness, vehicle speed zero |
LURBMIKH |
reference value for engine roughness, vehicle speed zero and catalyst heating |
LURFOST |
engine roughness referenz value for stop of the fuel-on/-off adaptation |
LURKHE |
Engine roughness reference corr. value at cat heating in 1. interval |
LURMIN1 |
speed dependensy of engine roughness referenz minimum value 1 |
LURMIN2 |
speed dependensy of engine roughness referenz minimum value 2 |
LURMIN3 |
speed dependensy of engine roughness referenz minimum value 3 |
LURMINKHE |
engine roughness referenz minimum value during cat-heating in 1. interval |
LURST |
reference correction factor for engine roughness, after start |