MDZW 1.120 (Calculating Torque at the Desired Ignition Angle)

From Nefmoto

Revision as of 11:47, 22 May 2012 by TTQS (Talk | contribs)

Jump to: navigation, search

MDZW 1.120 Function Description

When calculating the desired ignition angle there are three different cases:

1. Torque influence on the ignition angle active (B_zwvs = 1)

2. Switching off torque influence on the ignition angle (B_zwvs = 0, dmaufr_w> 0)

3. Torque influences inactive (B_nozwe = 1)


1. Active Torque Intervention


The enable condition (B_zwvs) condition is set and the switch-off condition for the ignition angle intervention (B_nozwe) is false. The desired ignition angle is calculated from the torque requirement for the ignition path mizsol_w. The perturbation ramp (dmaufr_w) is zero. The requested torque mizsol_w is converted into the desired efficiency etazws. This is done by dividing by the optimum torque, which is calculated by multiplying miopt_w with the efficiency etazaist. The desired efficiency (etazws) is converted via the inverse ignition angle efficiency characteristic DZWETA into a delta-ignition angle (dzws). The difference between the optimum ignition angle zwopt and dzws gives the desired ignition angle zwsol.


2. Switching off the Torque Influence


When switching off the torque intervention (B_zwvz = 1®0, see %MDKOG), the desired torque mizsol_w can jump to a higher value. This positive torque perturbation must be prevented for driveability reasons. This is done by eliminating the requirement B_zwvz. A perturbation ramp dmaufr_w is reset, which initialises the amplitude of the jump and runs down to zero with a speed-dependent rate. This ramp is subtracted from the input mizsol_w and ensures a smooth transition into a state without any intervention within the timeframe. In this state B_zwvs = false, the switch-off condition for the ignition angle intervention B_nozwe is set but only after the ramp.


A special case is the anti-judder feature intervention, in which B_zwvs, but not B_zwvz is set. When the anti-judder torque requirement is eliminated from input mizsol_w, there is no jump, so that the switch-off ramp in this case is not necessary.


3. Torque Influences Inactive


In this state, no requirement is active (B_zwvs = 0) and the ramp dmaufr_w is screened. The switch-off condition for the ignition angle intervention B_nozwe is set. In this case, the desired ignition angle zwsol for the ignition is not taken into account (c.f. %ZUE) so the calculation can be omitted.


MDZW 1.120 Application Notes


The values ​​are in DMAUFN are preset to give a slope of approximately 5%/sec for all engine speeds.


Parameter

Description

DMAUFN

Delta torque control after engine torque intervention

DZWETA

Inverse delta ignition angle efficiency

Variable

Description

B_NOZWE

Condition flag: no ignition angle intervention on the engine torque structure

B_ZWVS

Condition flag for fast external ignition angle intervention on the torque interface

B_ZWVZ

Condition flag for ignition angle intervention on the torque interface

DMAUFR_W

Delta “up regulation” torque

DZWS

Delta ignition angle between zwopt and zwsol

ETAZAIST

Actual cylinder suppression efficiency

ETAZWS

Desired ignition angle efficiency

MIBAS_W

Indicated basic torque

MIOPT_W

Optimum indicated torque

MISOL_W

Indicated resulting desired torque

MIZSOL_W

Indicated resulting desired torque for ignition angle intervention

MIZWMN_W

Indicated engine torque at the latest ignition angle

NMOT W

Engine speed

REDIST

Actual reduction stage

R SYN

Synchronisation grid

ZWOPT

Optimum ignition angle

ZWSOL

Desired ignition angle for torque intervention

Personal tools