ZUE 282.130 (Fundamental Function - Ignition)

From Nefmoto

Jump to: navigation, search

See the funktionsrahmen for the following diagrams:

zue-zue

zue- dzwll


ZUE 282.130 Function Description

The ignition angle (zwgru) from the fundamental ignition angle calculation is corrected by the warm-up angle (dzwwl) and the cylinder-specific knock control angle (dwkrz), and it follows that the basic ignition angle (zwbas) is identical with the earliest possible ignition angle. This ignition angle now forms the route in to the ignition engine torque implementation (MDZW), which provides the output ignition angle (zwsol). This ignition angle is now limited to the earliest or latest possible ignition angle. The resulting ignition angle (zwist) is corrected by the phase error which gives the output ignition angle (zwout).


For back-up protection of the ignition angles, the one’s complement (i.e. inverse binary value) of zwout is calculated which forms zwoutcpl. This then becomes the input variable of the function monitor.


The cylinder bank selective ignition angle adjustment is activated via the codeword CWDZWLL = 1.

The delta ignition angle (dzwll) corresponding to B_bankl2 is added to, or subtracted from zwsol.

ZUE 282.130 Application Notes

Three interfaces are provided for the application; the RAM cell vszw and the fixed value ZWAPPL ZW enable adjustment of application tools. Engagement of the torque functions can be disabled using the codeword CWMDAPP (bit 0), so that the applied ignition angle (zwbas) can be driven directly.


Abbreviations

Parameter

Description

CWZWBANK

Codeword for enabling cylinder-specific ignition angle offsets

FZIZWV

Factor for torque correction via cylinder-specific ignition angle adjustment

KFDZWLL

Map for delta ignition angle during idle

KLZWBSMN

Latest possible basic ignition angle

TMZIZWV

Engine temperature threshold for enabling cylinder-specific ignition angle adjustment

VZIZWV

Vehicle speed threshold for disabling cylinder-specific ignition angle adjustment

WPHN

Phase response

ZWAPPL

Application interface: ignition angle adjustment

Variable

Description

B_BANK2

Condition flag for cylinder bank 2

B_LL

Condition flag for idle

B_LLREIN

Condition flag for idle control active

B_NOZWE

Condition flag for no ignition angle intervention in the torque structure

B_SA

Condition flag for overrun fuel cut-off

B_ZWAPPL

Condition flag for ignition angle application without torque intervention

B_ZWKRA

Condition flag for ignition angle output during knock regulation

CWDZWLL

Codeword for delta ignition angle during idle active

DWKR

Cylinder-specific ignition angle retardation during knock control

DZWBANK

Cylinder bank-specific ignition angle offset

DZWOB

Delta ignition angle during overboost

DZWWL

Delta ignition angle during warm-up

DZWZK

Delta ignition angle during knock

MISOLZ_W

Indicated resulting desired torque for ignition angle intervention

MIZSOL_W

Indicated resulting desired torque for ignition angle intervention

NMOT

Engine speed

NSOL

Desired idle speed

REDIST

Actual reduction stage

RL

Relative cylinder charge

SY_REDMX

System constant: maximum reduction stage

SY_TDZW

System constant: additive ignition angle adaptation active

SY TURBO

System constant: turbocharger

SY_WMAX

System constant: earliest outputtable ignition angle

SY_WMIN

System constant: latest outputtable ignition angle

SY_ZIZWV

Text must be provided by Mrs Sauer

SZOUT_W

Closing time output

TMOT

Engine temperature

VFZG

Vehicle speed

VSTDZW

Additive ignition angle adaption

VSZW

Ignition angle correction adjusting system

WKRDY

Ignition angle retardation via dynamic knock regulation

WPHG

Ignition angle speed sensor phase correction

ZNACHANZ

Number of ignitions in overrun

ZWBAS

Basic ignition angle

ZWDLLPRT

Ignition angle pointer with delta idle ignition angle

ZWGRU

Fundamental ignition angle

ZWIST

Actual ignition angle

ZWOUT

Ignition angle output

ZWOUTCPL

One’s complement of the ignition angles for function monitoring

ZWOUTPRT

Ignition angle pointer

ZWSOL

Desired ignition angle for torque intervention

ZWSPAE

Latest ignition angle

ZWSTT

Ignition angle during start

ZWZYL1

Ignition angle for cylinder 1

ZZYLZUE

Dwell angle-cylinder counter for calculating ignitions